7
AC6.E Sugar Dispenser – Tube Changing Procedure (All Models)
1. Place the dispenser on a level countertop.
Unplug the dispenser
.
2. Turn the black valve thumbscrew
counterclockwise.
Open the valve door.
3. Remove the black thumbscrew at the base of
the hopper on the back of the dispenser.
4. Lift the hopper carefully, straight up off the
dispenser base.
•
Do not
pull on the cord that connects the
control panel to the circuit board.
5.
Lay the dispenser on its side
•
Do not
unplug or pull on the control panel
cord.
6. Examine the dispensing tube.
7. If the tube is older than 30 days or is cut or
cracked, it must be replaced immediately.
Remove the old dispensing tube by pulling it
off the white fitment.
8. Replace with a new dispensing tube – slowly
turn the tube as you push it on the white
fitment.
9. Replace the hopper on the base.
10. Replace and hand-tighten the black hopper
thumbscrew by turning it clockwise.
11. Ensure the dispensing tube is aligned in the
center of the dispense valve.
Do not kink or twist the tube.
12. Close the valve door by inserting the black
valve thumbscrew and turning it clockwise.
Do not over-tighten.
13. If necessary, use sharp scissors to cut off any
excess tube hanging below the bottom of the
dispense valve to about ¼”.
14. Reconnect to the power source.
15. Push any button and the valve will open and
close.
The dispenser is now ready to be loaded with