396
-
5477Y1 Sentinel Row Control Manual
©2022 SurePoint Ag Systems 49
4/29/2022
SETUP for Rate Control
-
TESTS
-
Nozzle Test
(v 1.3.0 and later)
From the Product Setup page press the Nozzle Test icon.
Be sure MASTER is OFF. Press NEXT.
1
Select which sections you want to run for this test. NEXT
.
Enter SPEED and RATE. NEXT.
Turn MASTER ON to start the test. Monitor Actual Rate, Pressure, Flow per Minute, Duty Cycle and Pump RPM.
To stop the test, turn MASTER OFF.
If only a few rows are on, the system may struggle to main-
tain a smooth output and rate.
When testing with water, the pressure will be less than it will
be with a heavier, thicker fertilizer.
Increase the speed or rate to increase the pressure.