5477Y1 Sentinel Row Control Manual
©2022 SurePoint Ag Systems 42
4/29/2022
SETUP for Row Control
-
SETUP
-
Control Speed
-
Flow Cal
-
PWM Max and Min
1.) Press the center
SETUP
tab.
Start with the following settings. Adjust as needed.
Ctrl Mode
-
PRESSURE
Ctrl Speed
-
Start at 500 for PR hydraulic pumps
Tower Electric
-
2000
-
3000
Adjust as needed in the field. Increase the Ctrl
Speed if the pump is slow to adjust. Decrease the
Ctrl Speed if the pump fluctuates and the PWM Duty
Cycle does not settle into a narrow range going
across the field.
RPM Cal
-
15 (for hydraulic pumps equipped with
RPM sensor)
Max RPM
-
500 (Can be set to 550 if needed)
Flow Cal
-
2000
-
most PR hydraulic pump systems
0.6 to 13 gpm flowmeter and larger.
3000
-
most electric pump systems
0.3 to 5 gpm and smaller
(Flow cal number is on serial number sticker on side
of flowmeter)
PWM Max
-
80 to 100
PWM Min
-
20
-
25 for most hydraulic pumps.
5
-
10 for most electric pumps.
Start Boost
-
usually 0. Can be set slightly higher
than normal PWM Duty Cycle for a startup boost.
Open PWM
-
Normally RED. Turn to GREEN if you
want the pump to continue running for product agita-
tion while you turn around. When doing that, enter a
PWM % to set the pump speed for agitation (usually
30
-
40%)
2.) DIAGNOSTIC TAB
-
Observe the system param-
eters during operation.
3.)
SurePoint
-
press for version information
4.) Press starburst for Auxiliary Settings Screen and
to enter Unlock Code.
Do not use this screen without authorization.
Operate Tab:
Target Pressure: Start with pressure at 30 PSI.
Typical range will be from 20 to 45 PSI. Experiment
for smoothest operation with quick adjustment.
Tank Volume:
Enter tank volume when tank is filled.
This screen will show volume remaining in tank.
1
2
3
Tank Volume
SurePoint
Ag
Systems