42
USER MANUAL
www.surelight.com
3. Chart of Recommended Feed Cable Length According to Power Consumption
This chart only applicable to input voltage of 24V DC
WattS of Light
22AWG
/
0
.
34mm
²
20AWG
/
0
.
53mm
²
18AWG
/
0
.
82mm
²
17AWG
/
1
.
04mm
²
16AWG
/
1
.
38mm
²
14AWG
/
2
.
07mm
²
12AWG
/
3
.
29mm
²
10AWG
/
5
.
62mm
²
10W
20W
30W
40W
50W
60W
70W
80W
90W
100W
110W
120W
36m
18m
12m
8m
6m
5m
/
/
/
/
/
/
60m
30m
20m
15m
12m
10m
8m
6m
4m
/
/
/
100m
50m
30m
22m
18m
15m
12m
10m
7m
5m
3m
2m
120m
60m
38m
28m
22m
18m
14m
11m
8m
6m
4m
2.5m
140m
70m
45m
35m
28m
22m
18m
14m
10m
7m
5m
3m
240m
120m
80m
60m
48m
36m
30m
24m
18m
12m
8m
0m
400m
200m
130m
95m
75m
60m
50m
40m
30m
22m
1 5m
8m
600m
300m
200m
140m
105m
88m
72m
58m
45m
32m
22m
12m
Note:
1.Please adhere to parameters in below chart, feed cable length longer than what specified here will create voltage drop and eventually affect the lumen output of light.
2.The 0.3m feed cable length attached to front connector is not included in this cart
3. Feed cable length over 10m is NOT recommended unless special circumstances, especially for pixel addressable lights.
Appendix
Target D
uv
D Tolerance Range
uv
Nominal CCT
Target CCT and tolerance(K)
Flexible CCT
(2200-6500K)
1)
2)
T
Δ
T
F
±
D
uv
3)
T
F
Remark:
1) T is chosen to be at 100K steps
F
(2300,2400,……,6400K),excluding
the ten nominal CCTs listed in Table 1.
8
3
2)
Δ
T=1.1900x10 xT -
4
2
1.5434x10 xT +0.7168xT-902.55
3) Same as in the D Tolerance Range.
uv
1
.Correlated Color Temperature (CCT)
ANSI
STANDARD
Nominal CCT Categories
2200K
2500K
2700K
3000K
3500K
4000K
4500K
5000K
5700K
6500K
2238 ±102
2460±120
2725 ±145
3045±175
3465±245
3985±275
4503±243
5029±283
5667±355
6532±510
0.0000
0.0000
0.0000
0.0001
0.0005
0.0010
0.0015
0.0020
0.0025
0.0031
Tx:CCT of the source
For Tx<2870K
0.000±0.0060
For Tx≥2870K
Duv(Tx)±0.0060
where
Duv(Tx)=57700 x (1/Tx)2
-44.6 x (1/Tx)
+0.00854