Remarks: the bolts of input line and output line of power source of controller must
be tightened according to the required torque. Because binding post and circuit board
adopt electrical welding process, excessively high tightening torque will damage binding
post of controller and lead to the
breakdown
of binding post.
!
Warning:
●
Input line and output line of power source must be
same
with the symbols
on controller. Red line on positive pole of power source is connected to “+” of
controller. Black line on negative pole of power source is connected to “-” of
controller. The output end of controller is connected to phase line of
DC
motor
. “Y” end is connected to yellow line of
DC motor
. “G” end is connected
to green line of
DC motor
. “B” end is connected to blue line of
DC motor
.
Otherwise, controller will be damaged or
cannot
start
properly
.
●
Before
start
the above work, disconnect
air circuit breaker
and power source
or take battery down.
18.2Checking of controller
Check the wire of controller
regularly make sure the wire is not
loose and
still
insulati
ng
.
19
、
Electrical failure
diagnosis and troubleshooting
Refer to the following table or failure diagnosis content for electrical failure checking and
troubleshooting
of
bike
.
fault
possible reason
method
solution
bike has
battery is not
installed in bike or
power line is not
plugged into
battery
check plug of battery
install battery and
plugged in
air circuit breaker
in front of battery
has not been
opened
check air circuit breaker
turn on air circuit breaker
low battery
protection of
battery
turn off air circuit breaker,
use multimeter to check
whether output voltage of
battery is normal
(DC45V-67.2V)
charge battery
battery enters low-
temperature
protection or high-
temperature
protection
check whether ambient
temperature is lower than
-20
℃
or battery
temperature is too high
charge it after ambient
temperature becomes
suitable (-20
℃
-70
℃
)
protective tube of
main cable is fused
check state of protective
tube
replace protective tube