 When “01” is keyed in,  the value will appear on the display
as shown below:

LCard:01 Comd:F7

LCard:01 Comd:F7

LCard:01 Comd:F7

LCard:01 Comd:F7

LCard:01 Comd:F7

Op:36 Cd:01 Sc:__

Op:36 Cd:01 Sc:__

Op:36 Cd:01 Sc:__

Op:36 Cd:01 Sc:__

Op:36 Cd:01 Sc:__

Note that “Sc” is not used and stays blank. After the value is
entered at “Cd:”, press [ACK] or  [Escape] to save the changes.

NOTE:  If the [Escape] button is pressed before the value
at “Cd:” is entered, the changes will not be saved.

Verifying Data

• To verify the changes just entered, press and hold the [ACK]

button on the DRL-MX until this message is displayed:

Display Options

Display Options

Display Options

Display Options

Display Options

ACK:menu SEL:sel

ACK:menu SEL:sel

ACK:menu SEL:sel

ACK:menu SEL:sel

ACK:menu SEL:sel

• Press the [SELECT] button to view the system configuration;

this message will be displayed:

L01 #00

L01 #00

L01 #00

L01 #00

L01 #00

00

00

00

00

00

LCard Numb: 05

LCard Numb: 05

LCard Numb: 05

LCard Numb: 05

LCard Numb: 05

Press the [ACK] button to scroll forward through the configuration
displays until you reach option 36, or press the [SELECT] button
to scroll backwards through the configuration displays. Press
[ACK] and [SELECT] together to return to the Stand-By Mode.

Entering Commands

Commands are entered on the CPM2 keypad using the following
format: LCard; Comd; Op; Cd; Sc

• LCard: “Line Card” is the Line Card number; enter a

hexadecimal number from 01 to 0E for Line Cards 1 through
14.

• Comd: “Command” is the Command; enter a command from

the list above

• Op: “Option” indicates a function that is part of a command;

the following sections of this manual will explain which
 commands have options. Enter a 2-digit hexadecimal number

• Cd: “Code” is the code or value to be programmed for the

Option; enter a 2-digit hexadecimal number

• Sc: “Second Code” is a code or value that is only used with

SCADA commands; if required, enter a 2-digit hex number

Entering Data

The following is how to enter the Programming Password and
program an option in the F7 Options Programming section:

• Press and hold the [C] button on the CPM2 until the CPM2

displays the following message:

Enter PASS-WORD

Enter PASS-WORD

Enter PASS-WORD

Enter PASS-WORD

Enter PASS-WORD

****

The default password is “CAFE”. Enter the password using
the CPM2 keypad.

• When the password is entered, the CPM2 will display this

message:

LCard:__ Comd:__

LCard:__ Comd:__

LCard:__ Comd:__

LCard:__ Comd:__

LCard:__ Comd:__
Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

• Enter the Line Card number. In this example, Line Card 01

will be used. When “01” is keyed in, the number will appear
on the display as shown below:

LCard:01 Comd:__

LCard:01 Comd:__

LCard:01 Comd:__

LCard:01 Comd:__

LCard:01 Comd:__
Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

• Enter the Command number. In this example, the F7 Options

Programming command will be used. When “F7” is keyed
in, the command will appear on the display as shown below:

LCard:01 Comd:F7

LCard:01 Comd:F7

LCard:01 Comd:F7

LCard:01 Comd:F7

LCard:01 Comd:F7
Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

Op:__ Cd:__ Sc:__

• Enter the Option number. In this example, Option [36] will

be changed. When “36” is keyed in, the Option will appear
on the display as shown below:

LCard:01 Comd:F7

LCard:01 Comd:F7

LCard:01 Comd:F7

LCard:01 Comd:F7

LCard:01 Comd:F7
Op:36 Cd:__ Sc:__

Op:36 Cd:__ Sc:__

Op:36 Cd:__ Sc:__

Op:36 Cd:__ Sc:__

Op:36 Cd:__ Sc:__

• Enter the value to be programmed at Option 36. In this example,

01 will be programmed at Option [36] to enable it.

firealarmresources.com

Summary of Contents for SG Security MLR-MX

Page 1: ...MLR MX and Sure Signal CSR Installation and Operation Manual Version 1 0 firealarmresources com...

Page 2: ...ouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Increase the separation between the equipment and receiver Connect the equipment int...

Page 3: ...8 Radio Status 8 Radio Status Printer Outputs 8 Max Account Limits 8 User Programming 8 Entering Commands 9 Entering Data 9 SG CPM2 Central Processing Module 10 General Information 10 Features 10 CPM...

Page 4: ...onditions are reported on the LCD screens and sent to the MLR MX Backplane Connection Diagram P6 MV3 MV2 P5 P4 P2 R13 R11 R4 R6 R7 R12 printer and the computer The DRL MX Line Card Module verifies com...

Page 5: ...t is suggested that the receiver be tested before actual installation becoming familiar with the connections and setup of the unit on the work bench will make final installation more straightforward T...

Page 6: ...sed cover each unused location with a blank plate Use only UL Listed components with programmable output on the MLR MX Ex UL Listed Buzzer part PKB5 3A0 UL Listed Relay part HAS 112 12 Grounding For m...

Page 7: ...id numbers for the line card The list will scroll through the hexadecimal numbers 01 to 0F 1 to 15 when the desired number is displayed press the ACK and CANCEL buttons together The serial connection...

Page 8: ...the alarm messages in the event buffer will be transmitted to the CPM2 Display Program Version PROGRAM VERSION PROGRAM VERSION PROGRAM VERSION PROGRAM VERSION PROGRAM VERSION ACK menu SEL sel ACK men...

Page 9: ...etwork name The printer will then print L11 Cantel L11 is the receiver and line number Cantel is the current network Note This network name does not need to be saved in the MLR MX 2D request network l...

Page 10: ...between the Sure Signal and the network The display will show the following message 5004455 22 5004455 22 5004455 22 5004455 22 5004455 22 Low Signal Low Signal Low Signal Low Signal Low Signal The p...

Page 11: ...tions will be set as reserved Option 01 Linecard Number this sets the Physical number on the linecard and all reports are reported using this linecard number Option 0F Mute Buzzer option This option i...

Page 12: ...to be programmed for the Option enter a 2 digit hexadecimal number Sc Second Code is a code or value that is only used with SCADA commands if required enter a 2 digit hex number Entering Data The foll...

Page 13: ...turn the ACK light OFF and silence the buzzer The ACK button is also used in the Configuration Mode to select menu items ACK light Flashes when a message is received from the Line Card and COM1 is dis...

Page 14: ...tions available on the CPM2 To enter the Configuration Mode press the Escape button this message will be displayed Enter MASTER ID Enter MASTER ID Enter MASTER ID Enter MASTER ID Enter MASTER ID Enter...

Page 15: ...knowledge signal is not received from COM1 When using the Star DP8340 printer the CPM2 is able to print in both red and black If an IBM compatible printer is selected the CPM2 will print in black only...

Page 16: ...message will be displayed Contrast Level Contrast Level Contrast Level Contrast Level Contrast Level Press the Enter button to increase the contrast press the Backspace button to reduce the contrast W...

Page 17: ...ts the number of times the CPM2 tries to resend the message to COM1 this value should be 1 during normal communication 06 represents the acknowledge received from COM1 To disable the diagnostics featu...

Page 18: ...displayed This message will be displayed Receiver Number Receiver Number Receiver Number Receiver Number Receiver Number 01 Chg to xx 01 Chg to xx 01 Chg to xx 01 Chg to xx 01 Chg to xx Enter a new r...

Page 19: ...0 45 Feb 23 07 30 45 AC Power LOST AC Power LOST AC Power LOST AC Power LOST AC Power LOST Standby Mode Message During normal standby operation this message will be displayed Feb 23 07 30 45 Feb 23 07...

Page 20: ...rd __ Comd __ LCard __ Comd __ LCard __ Comd __ LCard __ Comd __ Op __ Cd __ Sc __ Op __ Cd __ Sc __ Op __ Cd __ Sc __ Op __ Cd __ Sc __ Op __ Cd __ Sc __ LCard Enter a 2 digit hexadecimal number from...

Page 21: ...e messages will be displayed in order from the most recent to the oldest Press the Backspace button to scroll from the oldest message to the most recent When finished viewing the messages press the Es...

Page 22: ...e signal varies and it can support the maximum 63 byte data block transmission from the control panel When this optional protocol is selected all SIA information will be sent to the host computer usin...

Page 23: ...20 UPS CONNECTION P6 MV3 MV2 P5 P4 P2 R13 R11 R4 R6 R7 R12 P6 MV3 MV2 P5 P4 P2 R13 R11 R4 R6 R7 R12 firealarmresources com...

Page 24: ...rds CAFE 03 Number of Line Cards E 04 Printer Select Backup 0 Enable 1 05 COM1 Configuration Baud 1200 Data 7 bits Parity 2 06 COM1 Format 1 07 ACK Wait Delay 4 0 seconds 08 Heartbeat Select 30 second...

Page 25: ...nal for the CPM2 Contact the software manufacturer for a software upgrade Increase the acknowledge wait time with CPM2 Configuration Option 07 Check COM1 baud rate and communication format using CPM2...

Page 26: ...24 7C 0111 1100 125 7D 0111 1101 126 7E 0111 1110 127 7F 0111 1111 DEC HEX BINARY 128 80 1000 0000 129 81 1000 0001 130 82 1000 0010 131 83 1000 0011 132 84 1000 0100 133 85 1000 0101 134 86 1000 0110...

Page 27: ...B0 30 0 B1 31 1 B2 32 2 B3 33 3 B4 34 4 B5 35 5 B6 36 6 B7 37 7 B8 38 8 B9 39 9 C1 41 A C2 42 B C3 43 C C4 44 D C5 45 E C6 46 F C7 47 G C8 48 H C9 49 I CA 4A J CB 4B K CC 4C L CD 4D M CE 4E N CF 4F O...

Page 28: ...s in parts and workmanship and not to damage incurred in shipping or handling or damage due to causes beyond the control of SG Security Communications such as lightning excessive voltage mechanical sh...

Page 29: ...0 SG Security Communications A Division of Sur Gard Security Systems Ltd 401 Magnetic Drive Units 24 28 Downsview Ontario Canada M3J 3H9 Tel 416 665 4494 Fax 416 665 4222 Toll Free 1 800 418 7618 www...

Reviews: