background image

MAINTENANCE

The AC transformer comes with a 15 foot power cord and 
is designed for use with the control valve; the transformer 
should only be used in a dry location.

In the event of a power outage that is less than 24 hours, 
the control valve will remember all settings and time of 
day. After 24 hours, the only item that needs to be reset is 
the time of day and will be indicated by the time of day 
flashing. All other settings are permanently stored in the 
nonvolatile memory.

If a power loss occurs that is less than 24 hours and the 
time  of  day  flashes,  this  indicates  that  the  battery  is 
depleted. The time of day should be reset and the non-
rechargeable battery should be replaced. The battery is a 3 
Volt Lithium Coin Cell type 2032 and is readily available at 
most  stores.  To  access  battery  location,  remove  front 
cover.

 POWER LOSS AND BATTERY REPLACEMENT

+

ERROR MESSAGE: If the word “ERROR” and a number are 
alternately flashing on the display record the number and 
contact the dealer for help. This indicates that the control 
valve was not able to function properly.

 ERROR

+

+

+

Correct
battery

orientation

When replacing the battery, align

positives and push down to fully seat. 

Battery fully seated  

Battery replacement 

is 3 volt lithium 

coin cell 2032

ERROR

1003

This  appliance  is  manufactured  from  premium  quality 
material  and  assembled  in  safe  conditions  to  assure 
it is clean and sanitary. If installed and serviced correctly, 
this appliance will not infect or contaminate your water 
supply.  However,  as  in  any  'device'  plumbed-in  in  your 
water  distribution  system,  a  proliferation  of  bacteria

 

is  possible,  especially  in  case  of  'stagnant  water'. 
Therefore this appliance is equipped with a 'days override' 
feature,  that  will  automatically  rinse  the  resin  bed 
periodically, even in case of low or absence of water usage.

 

SANITIZING THE APPLIANCE

To  retain  the  appearance  of  the  appliance,  simply  wipe 
it with a damp cloth or clean it with a mild soap solution; 
never use abrasive cleaners, ammonia or solvents.

 

APPEARANCE

1

5

Summary of Contents for OXYLINE

Page 1: ...Installation Manual www pavirani com...

Page 2: ...n 5 6 Commissioning 7 8 Electronic control panel 9 13 Maintenance 14 15 For future reference fill in the following data EN INSTALLATION RECORD Serial number Model Iron Fe content inlet Manganese Mn co...

Page 3: ...use whendamaged Use a hand truck to transport the appliance To prevent accident or injury do not hoist the appliance over your shoulder Donotlaytheapplianceonitsside Keep these Instructions in a safe...

Page 4: ...o a power outlet which is installed in a dry location with the proper rating and over current protection OPERATING CONDITIONS AND REQUIREMENTS PREPARATION OF THE SYSTEM FOR INSTALLATION 4 Before insta...

Page 5: ...e of repairs It allows to turn off the water to the appliance while maintaining untreated water supply to the user INLET OUTLET WITH FACTORY BYPASS optional 2 3 4 1 1 mains water supply untreated wate...

Page 6: ...ecommend the use of a stand pipe with air trap To prevent backflow from the drainage system into the appliance always make sure to have an air gap between the end of the drain line and the drainage sy...

Page 7: ...y Step 2 Raise the ratchets with special attention see photo Pull out the element on which the controller is installedbypushingitgently NOTE YOU MUST BE PARTICULARLY CAREFUL NOT TO BREAK THE FASTENING...

Page 8: ...faucet nearby the appliance and let the water run for a few minutes until all air is purged and all foreign material that may have resultedfromtheinstallationiswashedout closethetap STEP 5 Gently pres...

Page 9: ...R SET 16 00 Step 3 SETTING THE TIME MINUTES Set proper figure of minutes by pressing the buttons or Pressing the button NEXT causes going to the next parameter You can go back to the previous step any...

Page 10: ...LISH With the buttons or you can change the language The user may select the following language versions English German French Spanish and Italian Press the button REGEN if you want to finish or NEXT...

Page 11: ...ption the system will additionally inform you with a buzzer about the planned service CUSTOM ALARM DISPLAY in this option the system will not additionally inform you with a buzzer about the plannedser...

Page 12: ...fivescreens Bypressingthebutton NEXT youcanswitch overbetweenthealternativescreens Thefirstscreenalwaysindicatesthecurrenttime The second screen indicates the amount of water expressed in litres per...

Page 13: ...T MODE To initiate the regeneration immediately you should press and hold the button REGEN The system immediately goes into the regeneration mode NOTE THISPROCESSCANNOTBECANCELLED In case the system i...

Page 14: ...let valve to appliance is CLOSED 2 outlet valve from appliance is OPEN 1 1 2 3 SERVICE POSITION 1 1 bypass valve is CLOSED 2 inlet valve to appliance is OPEN 3 outlet valve from appliance is OPEN WITH...

Page 15: ...r are alternately flashing on the display record the number and contact the dealer for help This indicates that the control valvewasnotabletofunctionproperly ERROR Correct battery orientation When rep...

Reviews: