background image

ELECTRONIC CONTROL PANEL

The system is configured in such way that it goes into the 
regeneration  mode  when  the  water  demand  is  lower 
(night hours). 

REGENERATION MODE

1

3

If  the  regeneration  is  initiated  on  a  given  day,  the 
message  „REGENERATION  TODAY”  appears  on  the 
screen.

REGENERATION MODE

The regeneration process starts automatically, and then it 
resets to the water treatment mode by itself. When the 
regeneration  is  completed,  the  system  starts  again  to 
supply the installation with the treated water.

MANUAL REGENERATION: 

Sometimes it is necessary  to 

initiate the earlier cycle of regeneration. It may be related 
to an intensive period of the system exploitation.

POSTPONED MODE: 

To initiate the regeneration manually 

and  define  its  time,  you  should  press  and  release  the 
button „REGEN”. „REGENERATION TODAY" appears on the 
screen, the system goes into the regeneration mode at the 
set  time  (you  can  change  the  time  of  regeneration  by 
reprogramming the hour according to the steps described 
previously).

If  pressing  the  button  „REGEN”  causes  an  error  display, 
pressing it again will cancel the whole procedure.

INSTANT MODE: 

To initiate the regeneration immediately, 

you  should  press  and  hold  the  button  „REGEN”.  The 
system  immediately  goes  into  the  regeneration  mode. 

NOTE! THIS PROCESS CANNOT BE CANCELLED.

In case the system is during the regeneration, it is possible 
to  supply  the  installation  with  untreated  water.  In  such 
situation you should set the BY-PASS valve in the BYPASS 
POSITION.

MAINTENANCE

Regularly the user should perform a basic check to verify 

       

if  the  appliance  is  functioning  correctly,  on  the  basis 
of the following control points:

1. Check settings of electronic control panel.

 

2. Measure the contamination level before and behind 

the appliance.

3. Check drain line from control valve; there 

 

shouldn't be any water flow (unless appliance 
is in regeneration).

4. 

Check appliance and surrounding area; there 

shouldn't be any water leakages.

 

ROUTINE CHECKS

Occasionally it may be necessary to put the appliance 
hydraulically in bypass, i.e. to isolate it from the water 
distribution system; f.e.:

in case of an urgent technical problem;

when it is not necessary to supply treated water 

to the house/application (refill swimming pool, 
irrigation,...).

 

BYPASSING THE APPLIANCE

SERVICE POSITION

 [1]

1. inlet valve to appliance is OPEN.
2. outlet valve from appliance is OPEN.

OFF

OFF

OFF

OFF

1

2

[1]

WITH FACTORY BYPASS (optional)

.

Summary of Contents for OXYLINE

Page 1: ...Installation Manual www pavirani com...

Page 2: ...n 5 6 Commissioning 7 8 Electronic control panel 9 13 Maintenance 14 15 For future reference fill in the following data EN INSTALLATION RECORD Serial number Model Iron Fe content inlet Manganese Mn co...

Page 3: ...use whendamaged Use a hand truck to transport the appliance To prevent accident or injury do not hoist the appliance over your shoulder Donotlaytheapplianceonitsside Keep these Instructions in a safe...

Page 4: ...o a power outlet which is installed in a dry location with the proper rating and over current protection OPERATING CONDITIONS AND REQUIREMENTS PREPARATION OF THE SYSTEM FOR INSTALLATION 4 Before insta...

Page 5: ...e of repairs It allows to turn off the water to the appliance while maintaining untreated water supply to the user INLET OUTLET WITH FACTORY BYPASS optional 2 3 4 1 1 mains water supply untreated wate...

Page 6: ...ecommend the use of a stand pipe with air trap To prevent backflow from the drainage system into the appliance always make sure to have an air gap between the end of the drain line and the drainage sy...

Page 7: ...y Step 2 Raise the ratchets with special attention see photo Pull out the element on which the controller is installedbypushingitgently NOTE YOU MUST BE PARTICULARLY CAREFUL NOT TO BREAK THE FASTENING...

Page 8: ...faucet nearby the appliance and let the water run for a few minutes until all air is purged and all foreign material that may have resultedfromtheinstallationiswashedout closethetap STEP 5 Gently pres...

Page 9: ...R SET 16 00 Step 3 SETTING THE TIME MINUTES Set proper figure of minutes by pressing the buttons or Pressing the button NEXT causes going to the next parameter You can go back to the previous step any...

Page 10: ...LISH With the buttons or you can change the language The user may select the following language versions English German French Spanish and Italian Press the button REGEN if you want to finish or NEXT...

Page 11: ...ption the system will additionally inform you with a buzzer about the planned service CUSTOM ALARM DISPLAY in this option the system will not additionally inform you with a buzzer about the plannedser...

Page 12: ...fivescreens Bypressingthebutton NEXT youcanswitch overbetweenthealternativescreens Thefirstscreenalwaysindicatesthecurrenttime The second screen indicates the amount of water expressed in litres per...

Page 13: ...T MODE To initiate the regeneration immediately you should press and hold the button REGEN The system immediately goes into the regeneration mode NOTE THISPROCESSCANNOTBECANCELLED In case the system i...

Page 14: ...let valve to appliance is CLOSED 2 outlet valve from appliance is OPEN 1 1 2 3 SERVICE POSITION 1 1 bypass valve is CLOSED 2 inlet valve to appliance is OPEN 3 outlet valve from appliance is OPEN WITH...

Page 15: ...r are alternately flashing on the display record the number and contact the dealer for help This indicates that the control valvewasnotabletofunctionproperly ERROR Correct battery orientation When rep...

Reviews: