24
Table 4: Parts List for Door Assembly
c) Cover all painted surfaces of the door to avoid damages.
d)
Using a wedging tool or flat head screwdriver, gently remove the old ¾” gasket (along with the old
silicone) from the door framing.
e) Apply a bead of high temperature silicone along the groove of the metal brackets.
f)
Place the new ¾” gasket around the door framing and cut any excess gasket with scissors. NOTE: It is
recommended to tape the extremity of the gasket for a cleaner result.
Give significant amount of time to allow the silicone to cure before reinstalling the door onto the firebox. A slight
resistance is expected when closing the door with the new ¾” gasket; the door will close normally after the gasket
has taken proper shape.
6.6 Replacement of Glass
SUPREME FIREPLACES INC. uses a high quality 5mm thick Pyroceram III / Keralite ceramic glass that can
withstand temperatures up to 704
o
C / 1300
o
F. It is recommended to perform a weekly visual check for any
damages or cracks on the glass.
WARNING: Avoid striking the glass and slamming the door shut. Never operate the unit with a broken
or damage glass.
CAUTION: Wear protective gloves when handling broken glass.
Refer to the following instructions for
replacing the glass:
a) Order the replacement kit for the FLAIR 34 glass (PYRO_24.2
5”X17” – X1, GSK_31_7 – 2X, and
GSK_75_7
– 1X).
b) Remove, clean, and dispose any broken glass from the door and the surroundings.
c) Remove the door from the firebox and place it face down on a soft surface. NOTE: Rotate the handle to
permit proper placing.
d) Using a w
edging tool or flat head screwdriver, gently remove the ¾” gasket (along with the silicone) from
the door framing.
e) Using a wrench, remove the 8 nuts fastened around the door framing.
f) Remove the first row of metal brackets (2 small and 2 big) and thin gasket.
g) Remove the damage glass and clean thoroughly the door framing from loose glass fragments.
h) Place the new glass onto the second row of thin gasket, centered with the door framing.
i) Place back the first row of metal brackets (2 small and 2 big) and thin gasket.
j) Using a wrench, fasten the 8 nuts around the door framing (do not over-tighten).
k) Apply a bead of high temperature silicone along the groove of the metal brackets.
l)
Place the ¾” gasket back into position.
Give significant amount of time to allow the silicone to cure before reinstalling the door onto the firebox.
Item
Code
Description
Qty
1
DR2110
Door frame assembly
1
2
DR_2600
Horizontal metallic bracket
4
2
DR_1588
Vertical metallic bracket
4
3
PYRO_24.25
”X17” Pyroceram glass
1
4
GSK_31_7
Thin gasket
2
5
GSK_75_7
Thick gasket
1
6
SF0031
Door latch
1
7
SF0032
Wood pull handle
1
Figure 6-1: Exploded View of Door Assembly