24
6.2 Parameter Setting
6.2.1 Weighing Parameters
No.
Range
Default
Description
Set
100
0~1
1
Load Weight Unit
Display Unit of Loading Weight.
0: kg; 1: t
[Internal Scale Unit is kg]
2: lb; 3:kp
[Internal Scale Unit is lb]
101
0~1
1
TOT Weight Unit
Display Unit of Totalized Loading Weight.
If Internal Scale Unit is kg, the options are:
0: kg; 1: t
If Internal Scale Unit is lb, the options are:
0: lb; 1:kp
102
0~3
3
Ton&kp Decimal
0: o; 1: o.o; 2: o.oo; 3: o.ooo
103
1~50
10
Display Division
[kg]
1, 2, 5, 10, 20, 50
If the Weight Variance is less than Display Division
value, the display value will not change.
104
0~200
50
Zero Range
[kg]
105
0~1
0
[*]
Signal Range
0: 0-20mV; 1: 0-5V
Operating Authorization: Administrator.
106
0~19
2
[Anti-Vibration] Digital Filter
Set Value
Cutoff
Frequency
Set Value
Cutoff
Frequency
0
None
10
None
1
11.2Hz
11
112Hz
2
8.0Hz
12
80Hz
3
5.6Hz
13
56Hz
4
4.0Hz
14
40Hz
5
2.8Hz
15
28Hz
6
2.0Hz
16
20Hz
7
1.4Hz
17
14Hz
8
1.0Hz
18
10Hz
9
0.7Hz
19
7Hz
[*]: ‘Reset Defaults’ operation has no effect on the parameter.