25
No.
Range
Default
Description
Set
107
0~2
2
[*]
Loadcell Channel [Selection]
0: LC-DN
[LC-DN to Lower Sensor; LC-UP Unused]
1: LC-UP
[LC-UP to Lower Sensor; LC-DN Unused]
2: LC-DN-UP
[LC-DN to Lower Sensor; LC-UP to
Upper Sensor]
Operating Authorization: Administrator.
Note:
Lower Sensor is the oil pressure sensor installed in the
lower oil chamber of arm-lifting oil cylinder.
Upper Sensor is the oil pressure sensor installed in the
upper oil chamber of arm-lifting oil cylinder.
108
0~2
0
Working Mode
0: Truck Mode
1: Mix Mode
2: Axle Type Mode
109
0~1
0
[*]
Position [Switch] Channel [Selection]
0: Double
1: Single
[*]: ‘Reset Defaults’ operation has no effect on the parameter.