42
R-AD: Real-time AD Value.
Message ‘Save’: It’s allowed to save the detection results.
Alarm Message: It’s not allowed to save the detection results.
【
Ent
】
: Save;
【
Menu
】
: Exit without saving.
Repeat the above steps for three times, if the variation of Span Compensation Coefficient is in
the allowable range, Span Compensation process will be completed.
Press key
【
Pause
】
to enter Pause state with red sign ‘
■
’ displaying.
Alarm
Description
Sulution
【
Too Small Signal
】
Weighing Result
< [
Calibrating
Weight
× 99%].
Check if the actual weight of the materials
in the wheel loader’s bucket is consistent
with the inputed Calibrating Weight.
Do ‘Oil Pressure Sensor Adjustment’ again.
Do ‘Wheel loader’s Idle Speed Adjustment’
again.
【
S.CMP Limit
】
Span Compensation Coefficient
is not in the allowed range
[0.0000~99.9999].
Do ‘Oil Pressure Sensor Adjustment’ again.