10
No.
Sign
Description
[9]
OK
Weighing Normal.
STALL
Stall Alarm [The operator has released the accelerator of wheel loader in weighing
process]: Acceleration Value < [400] Stall Alarm Point.
LOW
Lower Limit Alarm of Single-bucket-loading-weight:
Loading Weight < [401] Load Lower Limit.
HIGH
Upper Limit Alarm of Single-bucket-loading-weight:
Loading Weight > [402] Load Upper Limit.
UND-T
Undertime Alarm: Weighing Time < [403] Min. Weighing Time.
OV-T
Overtime Alarm: Weighing Time > [404] Max. Weighing Time.
[10]
USUER
User Name.
[11]
Bucket Count
The display area of ‘Bucket Count’ will change to red background if the key
【
Void
】
is pressed for ‘Cancel Totalizing’ or ‘Cancel Deducting’.
[12]
Deviation Value
Deviation Value = Totalized Loading Weight
-
Setpoint Value.
[13]
Totalized
Loading Weight
“Last Bucket” Prompt: The display area of ‘Totalized Loading Weight’ will change
to red background if ‘Negative Deviation Value<3t’, it means that the next bucket
may be the last one, the operator should determine the loading weight of the next
bucket according to the actual Negative Deviation Value.
[14]
Single-bucket-
loading-weight
The display area of ‘Single-bucket-loading-weight’ will change to flashing red
background while alarming.
[15]
NO USB
U-disk is not ready.
USB
U-disk is ready.
ADD
The present Single-bucket-loading-weight has been totalized to Totalized Loading
Weight.
NO ADD
The present Single-bucket-loading-weight has not been totalized to Totalized
Loading Weight because of alarming.
After totalizing, the present Single-bucket-loading-weight can be deducted from
Totalized Loading Weight via the key
【
Void
】
.
Refer to parameter [406] ‘Totalizing/Deducting Permission While Alarming’.
DED
The present Single-bucket-loading-weight has been deducted from Totalized Loading
Weight.
NO DED
The present Single-bucket-loading-weight has not been deducted from Totalized
Loading Weight because of alarming.
After deducting, the present Single-bucket-loading-weight can be totalized to
Totalized Loading Weight again via the key
【
Void
】
.
Refer to parameter [406] ‘Totalizing/Deducting Permission While Alarming’.