Supmeter BST106-B60S(L) Operation Manual Download Page 2

Preface 

Thank you very much for your purchase! 

This  manual  covers  safety  precaution,  technical  specification,  operation  interface,  installation& 

connection, function&operation and so on. In order to make the product running at its best, please read this 
manual in advance, and reserve it for the future reading. 

The technology update, function enhancement and quality improvement may lead to some differences 

between this manual and the physical product, please understand. 

Without our authorization, the contents of this manual are not allowed to be copied and reproduced.

 

Main Features: 

 

Applications:  Weight/Force  Display,  Peak  Value  Detection&Display  Holding,  Setpoint  DO 
Output and AO/Digit Transmission. 

 

4 Optional Setpoint DO  Output Modes: Weight  Limit DO  Alarm Mode, Weight Increment DO 
Output Mode, Weight Decrement DO Output Mode and Weight Section DO Output Mode. 

 

EMC design with high anti-jamming capability, suitable for industrial environment. 

 

32-bit ARM CPU with 48MHz clock & higher arithmetic speed. 

 

5 Red LED digital tubes for English character and digit display. 

 

Menu&Shortcut mode operation. 

 

24-bit  High-precision  and  high-speed 

-

A/D  conversion  module  with  1/1,000,000  internal 

resolution and sampling frequency 1280Hz. 

 

Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy 
when there is strong  vibration on the load receptor, and the rapid response capability  when  the 
weight signal changes. 

 

Optional weighing input 

signal mV, V and mA for connecting ‘

mV

Output Type Loadcell’, 

V

Voltage Output Type Weighing Transmitter’ and ‘

mA

Current Output Type Weighing 

Transmitter’.

 

 

Auto  Zero Initial  Calibration  after Power-on,  Auto Zero Tracking,  Zero Fine  Adjustment, Zero 
Calibration and Load Calibration functions available. 

 

Optional  Data  Calibration,  Segmenting  Span  Correction  and  Segmenting  Weight  Calculation 
functions. 

 

Auto-locking,  Key-locking,  Key-unlocking,  Digital  Setting&Calibration  and  I/O  Testing 
functions available. 

 

1 Definable normally open switch input [DI]. 

 

2 Relay switches with normally open and normally closed contacts for outputting upper limit and 
lower limit alarm signals. 

 

1 Optional and definable analog signal output [AO: 4~20mA / 0~20mA / 0~5V / 0~10V / 

]. 

 

Optional  RS232  and  RS485  communication  ports  for  connecting  Host  IPC/PLC  and  LED 
Remote Display. 

 

With  the  multitasking  mode,  the  processes  of  weighing,  alarm  output  and  signal  transmission 
will not be interrupted by parameter setting and the other operations. 

 

Summary of Contents for BST106-B60S(L)

Page 1: ...6 B60S L Weighing Force Measuring Controller Weight Force Display Peak Value Detection Display Holding Setpoint DO Output AO Digit Transmission Operation Manual V5 0 Changsha Supmeter Technological Co...

Page 2: ...d A D conversion module with 1 1 000 000 internal resolution and sampling frequency 1280Hz Special anti vibration digital filtering algorithm for ensuring the weighing stability and accuracy when ther...

Page 3: ...tpoint Parameters SEtP 19 6 2 4 Communication Parameters SErP 21 6 2 5 Display Parameters dISP 22 6 2 6 A Sample of Parameter Setting 23 6 3 F2 CAL SYSTEM CALIBRATION 24 6 3 1 Zero Calibration ZEro 24...

Page 4: ...y with the ground resistance being less than 4 Cable Laying Weighing signal analog signal and communication signal cables should be laid in pipes and do not lay them together with power cables Power S...

Page 5: ...mA for 8 350 loadcells Excitation Voltage Max Current 2 DC12V 100mA for weighing transmitter Optional weighing input signal mV V and mA for connecting mV Output Type Loadcell V Voltage Output Type Wei...

Page 6: ...t IPC PLC and LED Remote Display Operating Specification Operating Voltage DC24V 20 Max Power Consumption 5W Outline Size 107 60 100mm W H D Panel Cut out Size 94 47mm W H Operating Temperature 25 to...

Page 7: ...ode A Parameter 904 0 dE Default Set Key Name Description Key locking Key unlocking SET Setpoint parameters setting ZERO 0 ZEro Zero Calibration with Power down Protection and Clearing Tare Weight ZEr...

Page 8: ...g ZERO 0 Zero Calibration with Power down Protection and Clearing Tare Weight The controller will switch to Gross Weight display TARE T Manual Tare with Power down Protection The controller will switc...

Page 9: ...ure Replace the ADC module oV Ad Over ADC Range Weighing signal exceeds A D conversion range 1 Check if the loadcell is connected 2 Check if the capacity of loadcell is too small 3 Check if the loadin...

Page 10: ...1 Installation Outline Size W H D mm Front Panel Size W H mm Box Body Size W H mm Panel Cut out Size W H mm 107 60 100 107 60 93 46 94 47 Installation Mode 94 47 Panel Cut out Size Outline Size Front...

Page 11: ...ll be unstable Select weighing signal via setting Switch DIP1 DIP2 and Parameter 111 Weighing Signal Type Weighing Signal 0 19 5mV 0 20mA 0 2 5V 0 5V 0 10V DIP1 in rear panel Set Left mV Right mA Midd...

Page 12: ...eld Ground 8 DI1 Switch Signal Input 1 POWER DC24V 20 Power Input Port 9 DC DC Input 10 DC DC Input The metal shell should be grounded directly For separating the controller from the interference of t...

Page 13: ...ort Application Mode Parameter 212 AP AP 1 HL AP 2 HH AP 3 LL AP 4 SEC DO1 203 SET1 203 SET1 203 SET1 SET1 203 SET2 DO2 203 SET2 203 SET2 203 SET2 203 SET1 203 SET2 Connection Power on Zero Calibratio...

Page 14: ...ibration 19 5EV mV Data Calibration Input Parameters Total Capacity and Output Sensitivity of Loadcell 20EA mA Data Calibration Input Parameters Capacity Zero Value and Full Value of Current Output Ty...

Page 15: ...weighing test equipment to adjust the mV weighing signal interface for normalizing Span Coefficient to 1 mA V Exfactory Span Adjustment Use precision current source to adjust the mA V weighing signal...

Page 16: ...cell Capacity Loadcell Quantity Self weight of Load Receptor 103 dV 1 500 1 Scale Division 1 2 5 10 20 50 100 200 500 104 ZE 99999 99999 0 Zero Value Only for query 105 SP 0 1 0000 Span Coefficient Ma...

Page 17: ...4Hz 8 1 0Hz 9 0 7Hz Filter1 s 101 Digit Set Set Value Anti Vibration Grade 0 Medium 1 High 110 Sb 1 128 1 Weight Display Smooth Filter2 The bigger set value of Filter2 will make the weight display va...

Page 18: ...within this range Zero Fine Adjustment will be valid Suggestion Set value Scale Capacity 4 124 dZ 0 99 5 Range of Displaying Zero When the absolute value of weight is within this range the weight dis...

Page 19: ...90000 99999 Correction Point s AD Value 1 10 AD Value detected via Segmenting Correction Demand d1 d2 d10 Only for query 151 152 153 154 155 156 157 158 159 160 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA C10 0 01...

Page 20: ...205 dL 0 1 5 0 0 5 DO Bounce back Delay Time s Used for avoiding that the DO alarm switch turns on and off frequently with its related real time data being at the critical point Min Interval Time for...

Page 21: ...t without Power down Protection and without Clearing Tare Weight 1 ZEro Zero Calibration with Power down Protection and Clearing Tare Weight 2 tArE Manual Tare without Power down Protection 3 rStr Cle...

Page 22: ...inuous Sending ASCII 807 dA 0 3 2 Data for Continuous Sending Mode 0 groS Gross Weight 1 nEt Net Weight 2 dISP Displayed Characters 3 PnEt Net Weight Peak Value 808 SF 0 9 2 Continuous Sending Frequen...

Page 23: ...y keypad operation in one minute and it s not in the processes of F2 System Calibration F6 Factory Adjustment the controller will lock the keypad and return to Main Display Interface automatically 903...

Page 24: ...23 6 2 6 A Sample of Parameter Setting Modify the parameter 102 Scale Capacity Moving cursor Digit input Main Display Interface Exit Save M M...

Page 25: ...atically 6 3 1 Zero Calibration ZEro Do Zero Calibration without loading on the weigher and save the new Zero Value Exit Save M Main Display Interface M 104 Zero Value E XX XX Voltage Value mV U XX XX...

Page 26: ...on Note Total Capacity of Loadcells Loadcell Capacity Loadcell Number Voltage Ratio Excitation Voltage on the terminal of controller Excitation Voltage on the terminal of loadcells The rated excitatio...

Page 27: ...o access to get the specification parameter values for Data Calibration then it s necessary to do Load Calibration Prompt Message EA mA Data Calibration Main Display Interface M Input Total Capacity o...

Page 28: ...n parameter values for Data Calibration then it s necessary to do Load Calibration Prompt Message 2 5V 2 5V Data Calibration 5V 5V Data Calibration 10V 10V Data Calibration Main Display Interface M In...

Page 29: ...weight on the weigher to correct Span Coefficient further for higher weighing accuracy The loading weight should be bigger than 50 of Scale Capacity value Exit Save M Main Display Interface M Input C...

Page 30: ...rrection Points to get Span Correction Ratio of 10 linearity segments for higher weighing accuracy Main Display Interface M Loading Correction Point s Loading Weight 1 on the weigher Display AD Value...

Page 31: ...ameter 161 is used for opening closing the function of Segmenting Weight Calculation Display AD Value After AD Value is stable press 152 Span Correction Ratio 2 M Save Save Loading Correction Point s...

Page 32: ...oPEn 6 4 2 Key locking Locc Exit Enter M Main Display Interface F5 Loc Locc M If inputted password is correct Key locking will be valid Exit Enter M Main Display Interface F5 Loc oPEn M If inputted pa...

Page 33: ...M Main Display Interface F5 Loc PASS Input the new Password Please remember it M If inputted is Operator Password this operation interface will be skipped if inputted is Administrator Password Admini...

Page 34: ...40005 0 R 03 1 In Peak Value detection process 40005 1 40005 2 40005 3 40005 4 40005 5 40005 6 40005 7 40005 8 40005 9 40005 10 40005 11 40005 12 40005 13 1 Weight is stable 40005 14 1 Overload Alarm...

Page 35: ...ort 40008 W 06 0xA500 Unused 0xA501 Unused 0xA502 Unused 0xA503 Unused 0xA504 Unused 0xA505 Unused 0xA506 Unused 0xA507 Unused 0xA508 Unused 0xA509 Unused 0xA50A Clear Screen 0xA50B Manual Tare 0xA50C...

Page 36: ...10 Data Compared with Weight Setpoints UnShort 40026 R W 03 06 0 Gross Weight 1 Net Weight 2 Net Weight Peak Value UnShort 40027 R W 03 06 UnShort 40028 R W 03 06 UnShort 40029 R W 03 06 UnShort 40030...

Page 37: ...0123 4k DEC Weight Value 7 Bytes 30 39 2EH 0 9 Decimal Point Unit 1 Byte Space k t g 20 6B 74 67 Space None k kg Format B Displayed Characters Byte4 12 d 64 ID Code d Point Code 1 Byte 00 FF BIT7 0 Un...

Page 38: ...Unit 6B k 13 SUM CC SUM Byte1 Byte2 Byte12 14 END 0D CR 15 END 0A LF Example 2 Sending Displayed Characters 2 dISP Byte Field Name HEX Note 1 START 3D 2 Weighing State 53 S 3 Data Name 44 D 4 ID Code...

Page 39: ...Technological Co Ltd Address Building A6 Lugu International Industrial Park Changsha 410205 China Tel 86 731 85115100 Fax 86 731 85158100 Website www supmeter com E mail supmeter supmeter com CPC16 0...

Reviews: