10
4.2 Terminal
The set value of parameter [111]
‘
Weighing Signal Type
’
and the switch position of DIP1/DIP2 should be
matched with the actual weighing input signal.
To
【
V
】
/
【
mA
】
weighing signal, the terminal ‘SIG
-
’ and ‘EXC
-
’ should be shorted; otherwise, the
sampling signal will be unstable.
Select weighing signal via setting Switch DIP1/DIP2 and Parameter [111]
‘
Weighing Signal Type
’
Weighing Signal
0~19.5mV
0~20mA
0~2.5V
0~5V
0~10V
DIP1[in rear panel] Set
Left
【
mV
】
Right
【
mA
】
Middle
【
V
】
Middle
【
V
】
Middle
【
V
】
Internal DIP2 Set
Left
【
NC
】
Left
【
NC
】
Left
【
NC
】
Middle
【
5V
】
Right
【
10V
】
Parameter [111] Set
‘
19.5EV
’
‘20EA’
‘2.5V’
‘5V’
‘10V’
Default Set
√
DIP1
mV V mA
DIP2
NC 5V 10V
AO
COM2
AL
AH
AO+ AO-
B-
A+
SIG+ SIG- EXC- EXC+ TXD RXD GND
DC- DC+
LOADCELL
COM1
POWER
PG
mV
V
mA
DI1