6.3.10 I/O Parameters (-Io-)
No.
Sign
Parameter
Range
Default
Set
P800
P801
P802
-Ao1
-Ao2
-Ao3
AO1 Signal
AO2 Signal
AO3 Signal
0: None
1: Flow
2: Control Current
3: Load
4: Speed
5: From AI [4~20mA]
6: From Communication Port
7: Totalized Weight High-speed Pulse (4mA
→
20mA
→
4mA)
8: Totalized Weight Low-speed Pulse (4mA
→
20mA
→
4mA)
9: Batch Weight (Output
Capacity:
[P217]
„Batch Weight Setpoint‟)
1
2
0
P803
P804
P805
P806
-do1
-do2
-do3
-do4
DO1 Signal
DO2 Signal
DO3 Signal
DO4 Signal
0: None
1: Flow Upper Limit Alarm
2: Flow Lower Limit Alarm
3: Load Upper Limit Alarm
4: Load Lower Limit Alarm
5: Speed Upper Limit Alarm
6: Speed Lower Limit Alarm
7: PID Upper Limit Alarm
8: PID Lower Limit Alarm
9: Flow Positive Deviation Limit Alarm
10: Flow Negative Deviation Limit Alarm
11: Totalized Weight Low-speed Pulse
12: Auto Feeding Control Mode
13: Calibrating State
14: Running State
15: From DI1
16: From DI2
17: From DI3
18: From Communication Port
19: Feeder Start&Stop Control
20: Belt Weigher Start&Stop Control)
21: BatchEnd[ON] (Totalized Weight reaches to
Batch Weight Setpoint)
22: BatchEnd[OFF] (Totalized Weight reaches
to Batch Weight Setpoint)
0
0
0
0