40
6.3.5 Flow Parameters (Flou)
No.
Sign
Parameter
Range
Default
Set
P300
UnIt
Flow Display Unit
0: t/h
1: kg/min
2: kg/h
([P107] Scale Unit = kg)
0
0: kg/h
1: g/min
2: g/h
([P107] Scale Unit = g)
P301
-dot
Flow Decimal Point
0: o; 1: o.o; 2: o.oo
1
P302
rAng
Flow Range
0.01~5000.00t/h
([P107] Scale Unit = kg)
100.00
0.01~5000.00kg/h
([P107] Scale Unit = g)
P303
-HI-
Flow Upper Limit
(0.0~100.0)% Flow Range
100.0%
P304
-Lo-
Flow Lower Limit
(0.0~100.0)% Flow Range
0.0%
P305
FILt
Flow Filter
1~200
10
P306
FLt2
Flow Filter 2
1~100
The secondary filter for flow display.
1
P307
FdEV
Flow Deviation Range
for Filter2
±(0~20)%
When Flow Deviation [E%] is within
this range, the secondary filter will
work.
±2%
www.zemicusa.info