![Supmeter BST100-B11 Operation Manual Download Page 35](http://html1.mh-extra.com/html/supmeter/bst100-b11/bst100-b11_operation-manual_1406101035.webp)
34
6.2 Main MENU
Main Menu
Second Menu
Description
≡
F1-SEt
≡
Setting
--SCAL--
Basic scale parameters setting.
--SCAL1-
Extra scale parameters setting.
--CtrL--
Basic feeding control parameters setting.
--CtrL1-
Extra feeding and batching control parameters setting.
--Flou--
Flow parameters setting.
--SPEd-
Speed parameters setting.
--LoAd--
Load parameters setting.
--SAVE--
Weight record parameters setting.
--SErP--
Communication parameters setting.
---Io---
Input/output parameters setting.
--dISP--
Display and operation interface parameters setting.
--tIEE--
Date/Time parameters setting.
≡
F2-CAL
≡
Calibration
--ZEro--
Zero Calibration without loading for correcting Zero Value.
--LoAd--
Dynamic Span Calibration with loading materials or Poise Weights for
correcting Span Coefficient.
-CHAn--
Static Span Calibration with a measured chain weight as a continuous and
steady load on the running belt weigher for correcting Span Coefficient.
--HAng--
Static Span Calibration with a measured Hanging Weight as a steady load
on the running belt weigher for correcting Span Coefficient.
--SEgC--
Segmenting Span Correction. After doing Dynamic or Static Span
Calibration, further corrections for 3 [AD Value: 0~60000] linear segments
are optional for correcting Correction Coefficient 1~3.
--SPEd--
Speed Coefficient Calibration.
Keep the belt weigher running at a constant speed. After the running time of
a revolution being measured with using a stopwatch, do this operation for
correcting Speed Coefficient.
--LEnS--
Belt Length Calibration.
Keep the belt weigher running at a constant speed. After the running time of
a revolution being measured with using a stopwatch, do this operation for
correcting Belt Length.
≡
F3-rEC
≡
Weight Record
Query and print Weight Records.
www.zemicusa.info