Chapter 2: Server Installation
2-4
Installing the Server into a Rack
This section provides information on installing the SuperServer 6113M-i into a
rack unit with the rack rails provided. If the 6113M-i has already been mounted
into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of
rack units on the market, which may mean the assembly procedure will differ
slightly. You should also refer to the installation instructions that came with the
rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6113M-
i. Each of these assemblies consists of two sections: an inner fixed chassis rail
that secures to the 6113M-i (A) and an outer fixed rack rail that secures directly
to the rack itself (B). A pair of short brackets to be used on the front side of the
outer rails are also included.
Installing the Inner Rails
First, locate the right inner rail (the rail that will be used on the right side of the
chassis when you face the front of the chassis). Align the four square holes on
the right inner rail against the hooks on the right side of the chassis. Securely
attach the rail to the chassis with two M4 flat head screws. Repeat these steps
to install the left inner rail to the left side of the chassis.
Figure 2-1. Installing Rails to the SC813Hi with Rack Rails Attached
Summary of Contents for SuperServer 6113M-i
Page 1: ...SUPERSERVER 6113M i USER SMANUAL 1 0 SUPER...
Page 5: ...v Preface Notes...
Page 10: ...SUPERSERVER 6113M i User s Manual x Notes...
Page 18: ...SUPERSERVER 6113M i User s Manual 1 8 Notes...
Page 28: ...SUPERSERVER 6113M i User s Manual 2 10 Notes...
Page 69: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 4 Removing Replacing the Power Supply...