6-12 Power Supply
The system utilizes redundant, hot-plug 2000 W power supplies. They automatically
sense the input voltage between 100v to 240v, and operate at that voltage. An amber
light on the power supply is illuminated when the power is switched off. An green
light indicates that the power supply is operating.
Power Supply Replacement
If a power supply module must be replaced, it can be removed without powering
down the system. Replacement units can be ordered directly from Supermicro.
Changing the Power Supply (Figure 6-18)
1. On the rear of the chassis, unplug the AC power cord from the module.
2. Push the release tab on the back of the power module, as illustrated.
3. Pull the power supply out using the handle.
4. Push the new power supply module into the power bay until it clicks into place.
5. Plug the AC power cord back into the module.