Chapter 5: Advanced Serverboard Setup
5-5
Installing a Passive CPU Heatsink
1. Do not apply any thermal grease to the heatsink or the CPU die -- the re-
quired amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are
aligned with those on the serverboard and the heatsink bracket underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug
(do not over-tighten the screws to avoid possible damage to the CPU.)
4. Add the two remaining screws then fully tighten all four screws.
Removing the Heatsink
Warning:
We do not recommend removing the CPU or the heatsink. How-
ever, if you do need to remove the heatsink, please follow the instructions
below to prevent damage to the CPU or other components.
1. Unscrew the heatsink screws from the serverboard in the sequence as shown
described above.
2. Gently wriggle the heatsink to loosen it from the CPU (do not use excessive
force). Once the CPU is loose, remove the it from the CPU socket.
3. Clean the surface of the CPU and the heatsink, removing the used thermal
grease. Reapply the proper amount of thermal grease on the surface before
re-installing the CPU and the heatsink.
Figure 5-1. Installing the Heatsink
!
Screw #1
Screw #2
Screw #3
Screw #4
Summary of Contents for SUPERSERVER 6017R-TDF
Page 1: ...SUPERSERVER 6017R TDF SUPER USER S MANUAL 1 0...
Page 5: ...v Preface Notes...
Page 14: ...1 6 SUPERSERVER 6017R TDF User s Manual Notes...
Page 24: ...2 10 SUPERSERVER 6017R TDF User s Manual Notes...
Page 28: ...3 4 SUPERSERVER 6017R TDF User s Manual Notes...
Page 100: ...7 32 SUPERSERVER 6017R TDF User s Manual Notes...
Page 102: ...A 2 SUPERSERVER 6017R TDF User s Manual Notes...
Page 106: ...B 4 SUPERSERVER 6017R TDF User s Manual Notes...