Chapter 6: Advanced Chassis Setup
6-9
6-5 Power
Supply
6015B-UR/6015B-NTR
The SuperServer 6015B-UR/6015B-NTR has a 650 watt redundant power supply
confi guration consisting of two hot-swap power modules. The power supply mod-
ules have an auto-switching capability, which enables them to automatically sense
and operate with a 100V - 240V input voltage.
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full
load and allow the system to continue operation without interruption. The Universal
Information LED on the control panel will blink slowly and remain so until the failed
module has been replaced. Replacement modules can be ordered directly from
Supermicro (see contact information in the Preface). The power supply modules
have a hot-swap capability, meaning you can replace the failed module without
powering down the system.
Removing/Replacing the Power Supply
You do not need to shut down the system to replace a power supply module. The
redundant feature will keep the system up and running while you replace the failed
hot-swap module. Replace with the same model, which can be ordered directly
from Supermicro (see Contact Information in the Preface).
1.
Removing the power supply
First unplug the power cord from the failed power supply module. To remove the
failed power module, push the release tab (on the back of the power supply) to
the side and then pull the module straight out (see Figure 6-6). The power supply
wiring was designed to detach automatically when the module is pulled from the
chassis.
2.
Installing a new power supply
Replace the failed power module with another PWS-651-1R power supply module.
Simply push the new power supply module into the power bay until you hear a click.
Finish by plugging the AC power cord back into the module.
Summary of Contents for SUPERSERVER 6015B-NT
Page 5: ...v Preface Notes...
Page 10: ...Notes x SUPERSERVER 6015B UR 6015B U 6015B NTR 6015B NT User s Manual...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...
Page 30: ...3 4 SUPERSERVER 6015B UR 6015B U 6015B NTR 6015B NT User s Manual Notes...
Page 58: ...5 24 SUPERSERVER 6015B UR 6015B U 6015B NTR 6015B NT User s Manual Notes...
Page 69: ...Chapter 6 Advanced Chassis Setup 6 11 Figure 6 6 Removing Replacing the Power Supply...
Page 70: ...6 12 SUPERSERVER 6015B UR 6015B U 6015B NTR 6015B NT User s Manual Notes...
Page 96: ...7 26 SUPERSERVER 6015B UR 6015B U 6015B NTR 6015B NT User s Manual Notes...
Page 102: ...A 6 SUPERSERVER 6015B UR 6015B U 6015B NTR 6015B NT User s Manual Notes...
Page 108: ...B 6 SUPERSERVER 6015B UR 6015B U 6015B NTR 6015B NT User s Manual Notes...
Page 122: ...C 14 SUPERSERVER 6015B UR 6015B U 6015B NTR 6015B NT User s Manual Notes...
Page 126: ...D 4 SUPERSERVER 6015B UR 6015B U 6015B NTR 6015B NT User s Manual Notes...