Chapter 2: Server Installation
2-5
Installing the Chassis Rails
Position one of the fi xed chassis rail sections you just removed along the side of
the 5026T-3F/5026T-T. Note that these two rails are left/right specifi c. Slide the rail
toward the front of the chassis (see arrows in Figure 2-2) until you hear them click
into place with the retention hooks on the chassis. The screw holes should now be
aligned - screw the rail securely to the side of the chassis (see Figure 2-2).
Repeat this procedure for the other rail on the other side of the chassis. You will
also need to attach the rail brackets when installng into a telco rack.
Locking Tabs:
As you have seen, both chassis rails have a locking tab, which
serves two functions. The fi rst is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the server
from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 5026T-3F/5026T-T in the rack.
(See Rack and Server Precautions in Section 2-3.) Position the fi xed rack rail/sliding
rail guide assemblies at the desired location in the rack, keeping the sliding rail guide
facing the inside of the rack. Screw the assembly securely to the rack using the
brackets provided. Attach the other assembly to the other side of the rack, making
sure both are at the exact same height and with the rail guides facing inward.
Summary of Contents for SUPERSERVER 5026T-3F
Page 1: ...USER S MANUAL 1 0 SUPER SUPERSERVER 5026T 3F SUPERSERVER 5026T T...
Page 5: ...v Preface Notes...
Page 23: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...
Page 28: ...3 4 SUPERSERVER 5026T 3F 5026T T User s Manual Notes...
Page 96: ...A 2 SUPERSERVER 5026T 3F 5026T T User s Manual Notes...