Chapter 2: Server Installation
2-7
Figure 2-4. Installing the Server into a Telco Rack
Installing the Server into a Telco Rack
To install the SuperServer 5015M-Ni into a Telco type rack, use two L-shaped
brackets on either side of the chassis (four total). First, determine how far follow
the server will extend out the front of the rack. Larger chassis should be positioned
to balance the weight between front and back. If a bezel is included on your
server, remove it. Then attach the two front brackets to each side of the chassis,
then the two rear brackets positioned with just enough space to accommodate the
width of the telco rack. Finish by sliding the chassis into the rack and tightening
the brackets to the rack.