Chapter 2: Server Installation
2-3
2-4
Installing the SuperServer 5010H/5010E into a
Rack
This section provides information on installing the SuperServer 5010H/5010E
into a rack unit. If the 5010H/5010E has already been mounted into a rack,
you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack
units on the market, which may mean the assembly procedure will differ
slightly. The following is a guideline for installing the 5010H/5010E into a
rack with the rack rails provided. You should also refer to the installation
instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails:
You should have received two rack rail assemblies with the SuperServer
5010H/5010E. Each of these assemblies consist of two sections: an inner
fixed chassis rail that secures to the 5010H/5010E (A) and an outer fixed
rack rail that secures directly to the rack itself (B). A sliding rail guide
sandwiched between the two should remain attached to the fixed rack rail.
(See Figure 2-1.) The A and B rails must be detached from each other to
install.
To remove the fixed chassis rail (A), pull it out as far as possible - you
should hear a "click" sound as a locking tab emerges from inside the rail
assembly and locks the inner rail. Then depress the locking tab to pull the
Figure 2-1. Identifying the Sections of the Rack Rails
Mounting Holes
A
Locking Tab
B
inner rail completely out. Do this for both the left and right side rack rail
assemblies.
Summary of Contents for SUPERSERVER 5010E
Page 10: ...Notes SUPERSERVER 5010H 5010E User s Manual x...
Page 18: ...SUPERSERVER 5010H 5010E Manual 1 8 NOTES...
Page 30: ...2 12 SUPERSERVER 5010H 5010E Manual Notes...
Page 38: ...SUPERSERVER 5010H 5010E Manual 4 4 Notes...
Page 72: ...6 10 SUPERSERVER 5010H 5010E Manual Notes...
Page 112: ...SUPERSERVER 5010H 5010E User s Manual 7 40 BIOS Notes...
Page 124: ...SUPERSERVER 5010H 5010E Manual B 10 Notes...