3-3 LEDs
Power Failure LED
This red LED is illuminated only when a power failure occurs. The LED will illuminate
when any node is powered-on and one of the power supplies fails. This LED is off
during normal operation.
Node Status LEDs
The SC938BH-R1620B control panel features eight numbered node status LEDs,
which indicate the status of each motherboard node.
Figure 3-1. Node Status LEDs
LED Appearance
Description
Solid Green
The node is powered on and operating normally
Blinking Green
The node is in the process of shutting down
Solid Red
The node is detecting an overheated condition
1Hz Blinking Red
The node is detecting a fan failure
.25Hz Blinking Red
The node is detecting a power failure
Solid Blue
The node local UID is on
1Hz Blinking Blue
The node remote UID is on
No Illumination
The node is powered-down