Changing a System Fan
1. If necessary, open the chassis while the power is running to determine which
fan has failed. (Never run the server for an extended period of time with the
chassis cover open.)
2. Remove the failed fan's power cord from the backplane.
3. Lift the fan housing up and out of the chassis.
4. Push the fan up from the bottom and out of the top of the housing.
5. Place the replacement fan into the vacant space in the housing while making
sure the arrows on the top of the fan (indicating air direction) point in the
same direction as the arrows on the other fans.
6. Put the fan back into the chassis and reconnect the cable (see Figure 6-4
and Figure 6-5 for details).
7.
Confirm that the fan is working properly before replacing the chassis cover.
Figure 6-4. System Fan Placement
Summary of Contents for SUPERSERVER 6028TP-HC0R-SIOM
Page 1: ...USER S MANUAL Revision 1 0a SUPERSERVER 6028TP HTR SIOM 6028TP HC0R SIOM 6028TP HC1R SIOM...
Page 5: ...v SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 10: ...x Notes SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL...
Page 18: ...1 8 SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 26: ...2 8 SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 30: ...SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL 3 4 Notes...
Page 74: ...5 24 SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 136: ...A 2 SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 139: ...B 3 Appendix B System Specifications Notes...
Page 141: ...C 1 Appendix C Chinese Safety Warnings Appendix C Chinese Safety Warnings...