B-2
SUPERSERVER 6028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL
Chassis
-R2K04BP2 (2U rackmount)
Dimensions: (WxHxD) 17.25 x 3.47 x 28.5 in. (438 x 88 x 724 mm)
Weight
Gross (Bare Bone): 88 lbs. (40 kg.)
System Cooling
The system has four 8-cm PWM system cooling fans
System Input Requirements
AC Input Voltage: 100-240V AC auto-range
Rated Input Current: 16-12A (110-140V), 12.5-9.5A (180-240V)
Rated Input Frequency: 50 to 60 Hz
Efficiency: 80+ (Platinum Level)
Power Supply
Rated Output Power: 2000W (Part# PWS-2K04A-1R) (redundant, hot-plug)
Rated Output Voltages: +12V (167A), +5Vsb (1A)
Operating Environment
Operating Temperature: 0º to 35º C (32º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate” for further details.
Summary of Contents for SUPERSERVER 6028TP-HC0R-SIOM
Page 1: ...USER S MANUAL Revision 1 0a SUPERSERVER 6028TP HTR SIOM 6028TP HC0R SIOM 6028TP HC1R SIOM...
Page 5: ...v SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 10: ...x Notes SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL...
Page 18: ...1 8 SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 26: ...2 8 SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 30: ...SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL 3 4 Notes...
Page 74: ...5 24 SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 136: ...A 2 SUPERSERVER 6028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Page 139: ...B 3 Appendix B System Specifications Notes...
Page 141: ...C 1 Appendix C Chinese Safety Warnings Appendix C Chinese Safety Warnings...