Chapter 6: Advanced Chassis Setup
6-19
6-11 Power Supply
The chassis utilizes redundant, hot-plug 2000 Watt power supplies.
The power supplies are auto-switching capable. This enables them to automatically
sense and operate at a 100v to 240v input voltage.
Power Supply Replacement
The chassis utilizes two redundant power supplies. In the unlikely event
that the power supply unit needs to be replaced, one power supply can be removed,
without powering down the system. Replacement units can be ordered directly from
Supermicro (See the contact information in the Preface of this manual).
Changing the Power Supply (Figure 6-18)
1. Power down all four nodes and unplug the power cord.
2. Push the release tab (on the back of the power supply) as illustrated.
3. Pull the power supply out using the handle provided.
4. Push the new power supply module into the power bay until you hear a click.
5. Plug the AC power cord back into the module and power up the nodes.
Summary of Contents for SUPERSERVER 6028TP-HC0FR
Page 1: ...USER S MANUAL Revision 1 0a SUPERSERVER 6028TP HC0R 6028TP HC0TR 6028TP HC0FR...
Page 5: ...v SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...
Page 10: ...x Notes SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL...
Page 18: ...1 8 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...
Page 26: ...2 8 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...
Page 30: ...SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL 3 4 Notes...
Page 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 136: ...A 2 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...
Page 139: ...B 3 Appendix B System Specifications Notes...
Page 141: ...C 1 Appendix C Chinese Safety Warnings Appendix C Chinese Safety Warnings...