Chapter 2: Server Installation
2-5
Figure 2-2. Installing the Inner Rail Extensions
Installing the Inner Rail Extension
The chassis includes a set of inner rails in two sections: inner rails and
inner rail extensions. The inner rails are pre-attached to the chassis, and do not
interfere with normal use of the chassis if you decide not to use a server rack. The
inner rail extension is attached to the inner rail to mount the chassis in the rack.
Installing the Inner Rails (Figure 2-2)
1. Place the inner rail extensions on the side of the chassis aligning the hooks
of the chassis with the rail extension holes. Make sure the extension faces
"outward" just like the pre-attached inner rail.
2. Slide the extension toward the front of the chassis.
3. Secure the chassis with 2 screws as illustrated. Repeat steps for the other
inner rail extension.
1
1
1
2
1
3
1
3
Slide rail mounted equipment is not to be used as a shelf or a work space.
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Summary of Contents for SUPERSERVER 6028TP-HC0FR
Page 1: ...USER S MANUAL Revision 1 0a SUPERSERVER 6028TP HC0R 6028TP HC0TR 6028TP HC0FR...
Page 5: ...v SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...
Page 10: ...x Notes SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL...
Page 18: ...1 8 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...
Page 26: ...2 8 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...
Page 30: ...SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL 3 4 Notes...
Page 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 136: ...A 2 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...
Page 139: ...B 3 Appendix B System Specifications Notes...
Page 141: ...C 1 Appendix C Chinese Safety Warnings Appendix C Chinese Safety Warnings...