Chapter 5: Advanced Serverboard Setup
5-13
NIC2 (LAN2) LED
The LED connections for LAN2 are
on pins 9 and 10 of JF1. Attach LAN
LED cables to display network activ-
ity. See the table on the right for pin
defi nitions.
HDD LED
The HDD LED and UID switch con-
nections are located on pins 13 and
14 of JF1. Attach a hard drive LED
cable here to display disk activity. This
connection is also used for the front
panel UID switch. The UID LED on
pin 7 of JF1 works in conjunction with
this switch. See the table on the right
for pin defi nitions.
NIC1 LED
Pin Defi nitions (JF1)
Pin# Defi nition
11
Vcc
12
Ground
NIC2 LED
Pin Defi nitions (JF1)
Pin# Defi nition
9
Vcc
10
Ground
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition
13
UID Signal/3.3V
14
HDD Active
NIC1 (LAN1) LED
The LED connections for LAN1 are
on pins 11 and 12 of JF1. Attach LAN
LED cables to display network activ-
ity. See the table on the right for pin
defi nitions.
Overheat/Fan Fail/PWR Fail/UID
LED
Pins 7 and 8 of JF1 are for the Over-
heat/Fan Fail/Power Fail and UID
LED connections. The red LED (pin
8) provides warnings of overheat,
fan failure or power failure. The blue
LED (pin 7) is for the UID LED indica-
tor for the control panel UID button.
Refer to the tables on the right for
pin defi nitions.
OH/Fan Fail/ PWR Fail/Blue_UID
LEDPin Defi nitions (JF1)
Pin# Defi nition
7
Blue UID LED/5.5V.SB
8
OH/Fan Fail/PWR Fail/Red UID
LED
OH/Fan Fail/PWR Fail
LED Status (Red LED)
State Defi nition
Off
Normal
On
Overheat
Flashing
Fan Fail
Summary of Contents for SUPERSERVER 6026TT-IBQF
Page 5: ...v Preface Notes ...
Page 16: ...1 8 SUPERSERVER 6026TT TF IBXF IBQF User s Manual Notes ...
Page 54: ...5 22 SUPERSERVER 6026TT TF IBXF IBQF User s Manual Notes ...
Page 92: ...7 28 SUPERSERVER 6026TT TF BIXF BIQF User s Manual Notes ...
Page 94: ...A 2 SUPERSERVER 6026TT TF IBXF IBQF User s Manual Notes ...