Appendix F CPU-Based RAID for NVMe
165
Figure F-3. Created Volume
without
enabling RAID spanned over VMD
controller
Figure F-4. Created Volume
with
enabling RAID spanned over VMD
controller
6.
Press [F4] to save the configuration and reboot the system.
7. Press [DEL] to enter BIOS.
8. Switch to
Advanced > Intel(R) Virtual RAID on CPU > All Intel VMD Controllers >
Create RAID Volume
.
9. Set
Name
.
10. Set
RAID Level
.
11. If cross-controller RAID is required, select
Enable RAID spanned over VMD Controller
as shown in Figure F-4.
12.
Select specific disks for RAID with an [X].
•
RAID0: Select at least two [2 - 24] disks
•
RAID1: Select only two disks
•
RAID5: Select at least three [3 - 24] disks
•
RAID10: Select only four disks
13. Select
Strip Size
(Default 64KB).
14. Select
Create Volume
.
15. If another RAID is needed, start again at step 6.
16. Press [F4] to save and reboot.