SuperServer 1029P-N32R User's Manual

Figure E-1. Intel

®

 VROC RAID Key and Motherboard Connector JRK1

E.1  Hardware Key

The  Intel  VROC  hardware  key  is  a  license  key  that  detects  the  Intel  VROC  SKU  and 
activates the function accordingly. The key must be plugged into the Supermicro motherboard 
(connector JRK1). The key options are:

Intel

®

 VROC Keys

VROC Package

Description

Part Number

Intel MM Number

Standard

RAID 0, 1, 10  

Supports 3rd party SSDs

AOC-VROCSTNMOD

951605

Premium

RAID 0, 1, 5, 10  

Supports 3rd party SSDs

AOC-VROCPREMOD

951606

Intel SSD only

RAID 0, 1, 5, 10  

Supports Intel SSDs only

AOC-VROCINTMOD

956822

Additional Information

Additional information is available on the product page for the Supermicro add-on card and 
the linked manuals. 

www.supermicro.com/products/accessories/addon/AOC-VROCxxxMOD.cfm

Summary of Contents for SuperServer 1029P-N32R

Page 1: ...User s Manual Revision 1 0a SuperServer 1029P N32R...

Page 2: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful...

Page 3: ...drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp driver Product s...

Page 4: ...17 Rack Precautions 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mechanical Loading 18 Circuit Overloading 19 Reliable Ground 19 2 3 Installing...

Page 5: ...M from the Motherboard 35 Memory Installation 36 ESD Precautions 36 Precautions 36 Introduction to Intel Optane DC Persistent Memory 36 Memory Support 36 Memory Population Sequence 37 General Memory P...

Page 6: ...System 71 5 2 Driver Installation 72 5 3 SuperDoctor 5 73 5 4 IPMI 73 5 5 Firmware Updates 74 Updating Switch Configuration 74 Updating the BMC Firmware 76 Chapter 6 BIOS 6 1 Introduction 78 Starting...

Page 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermic...

Page 8: ...r supply air shroud MCP 310 13601 0N 1 Drive backplane FRU module for SC136 1U U 2 JBOF Server BPN FRU 136U2 2 1U Passive CPU heat sink for equipped with a Narrow Retention Mechanism SNK P0067PS 2 Ris...

Page 9: ...M DDR4 ECC 2933 2666 2400 2133 MHz speed memory in 24 memory slots Notes 1 2933 MHz memory is supported by the 82xx 62xx series processors only 2 Up to 9TB memory is supported with DCPMM modules insta...

Page 10: ...ates power is being supplied to the system power supply units This LED is illuminated when the system is operating normally 4 Information LED Alerts operator to several states as noted in the table on...

Page 11: ...op for each drive sixteen total These are explained below Sled Top Fault LEDs Sled Fault LEDs Status Description Off No failure Solid Red Drive failure Blinking Red 1 Hz RAID rebuild Blinking Red 4 Hz...

Page 12: ...I O ports 3 Expansion Ports Two PCI E expansion ports are accessible from the rear chassis Figure 1 3 Chassis Rear View Rear Features The illustration below shows the features included on the rear of...

Page 13: ...1 JP1 JPME2 PSU2 PSU1 JUIDB2 JL1 JBT1 JSDCARD1 JTPM1 JP_BSCAN_BMC M 2 JIPMB1 CN6 CN5 CN4 M 2 B37 A37 A1 B1 A1 A37 CN3 CN2 CN1 J30 J31 J30 LE2 S SATA4 S SATA5 VGA CPU2 SLOT2 PCIe 3 0X16 CPU1 SLOT1 PCIe...

Page 14: ...Table Jumper Description Default Setting JBT1 CMOS Clear Open Normal JP1 BIOS Advance Function Pins 2 3 Normal JP5 BMC Power Button Ready Test Header Pins 1 2 Normal JPB1 BMC Enable Disable Pins 1 2 E...

Page 15: ...IPMI JLAN1 JLAN2 10G LAN ports 1 and 2 JPWR1 JPWR2 Backplane power connectors JRK1 Intel VROC RAID key header for NVMe Solid State Devices SSD JSDCARD1 SD card socket JSD1 JSD2 SATA Disk On Module DOM...

Page 16: ...13 SPI LPC eSPI USB2 0 7 TPM Header HWM USB SPI MUX LPC eSPI PE PE 5 SPI FLASH 32MB BMC SPI FLASH 64MB BIOS IPMI LAN RJ45 COM1 PHY RTL8211F VGA NCSI DDR4 SPI BMC AST2500 DDR4 VGA LAN UART UPI port 0 1...

Page 17: ...ease read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where hea...

Page 18: ...er from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always ke...

Page 19: ...ch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The follow...

Page 20: ...6HTS R1K69P U2 chassis into a rack unit with the rails provided Due to the variety of rack units on the market the assembly procedure might differ slightly You should also refer to the installation in...

Page 21: ...e you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip over Releasing the Inner Rails Releasing the Inner Rails from the Outer Rails 1 Pull the inner rail out o...

Page 22: ...gainst the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the quick release bra...

Page 23: ...the Outer Rails on the Rack Installing the Outer Rails 1 If your rack has round mounting holes adjust the fittings on the outer rails Press the latch at the end of the rail to change from square fitti...

Page 24: ...outer rail into the rear rack holes An audible click indicates that the rail is locked into place 4 Press upward on the locking tab near the rear end of the middle rail and extend the outer rail unti...

Page 25: ...talling the Chassis onto the Rack Installing the Chassis onto the Rack 1 Fully extend the outer rails as illustrated in Figure 2 7 2 Align the inner rails of the chassis with the outer rails on the ra...

Page 26: ...the IPMI command interface 3 2 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing non hot swap componen...

Page 27: ...the second panel to the chassis 5 Slide the second panel toward the rear of the chassis and lift it off Warning Except for short periods of time do not operate the system without the cover in place T...

Page 28: ...otective cover is on the CPU socket and none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure on the LGA lands gold c...

Page 29: ...ier Assembly The processor carrier assembly contains the Intel Xeon Non Fabric Non F processor and a processor carrier 1 Plastic Protective Cover 2 CPU Socket 1 Non F Processor 2 Processor Carrier Ove...

Page 30: ...e Processor Heatsink Module The Processor Heatsink Module PHM contains a heatsink a processor carrier and the Intel Xeon Non Fabric Non F processor 1 Heatsink with Thermal Grease 2 Processor Carrier 3...

Page 31: ...s below 2 Using the triangles as a guide carefully align and place Point A of the processor into Point A of the carrier Then gently flex the other side of the carrier for the processor to fit into Poi...

Page 32: ...he processor carrier assembly so the processor s gold contacts are facing up then align the triangle on the assembly with hole 1 of the heatsink Press the processor carrier assembly down The plastic c...

Page 33: ...protective cover installed on the CPU socket Remove it from the socket to install the Processor Heatsink Module PHM Gently pull up one corner of the plastic protective cover to remove it CPU Socket wi...

Page 34: ...Turn the PHM right side up and you will see a triangle marked on the processor clip at the same corner of hollow triangle 3 Carefully align pin 1 the triangle on the the PHM against pin 1 the triangle...

Page 35: ...rocessor heatsink module PHM unplug power cord from the power outlet 1 Using a T30 Torx bit screwdriver turn the screws on the PHM counterclockwise to loosen them from the socket starting with screw m...

Page 36: ...Supermicro website for recommended memory modules Introduction to Intel Optane DC Persistent Memory Intel 82xx 62xx 52xx 42xx supports new DCPMM Optane DC Persistent Memory Modules technology DCPMM of...

Page 37: ...h DIMM Capacity GB Speed MT s One Slot per Channel Two Slots per Channel DRAM Density One DIMM per Channel One DIMM per Channel Two DIMMs per Channel 4 Gb 8 Gb 16 Gb 1 2 Volts 1 2 Volts 1 2 Volts RDIM...

Page 38: ...ow when populating memory modules Key Parameters for DIMM Configuration Key Parameters for DIMM Configurations Parameters Possible Values Number of Channels 1 2 3 4 5 or 6 Number of DIMMs per Channel...

Page 39: ...2 DIMMB1 P2 DIMMA1 P2 DIMMD1 P2 DIMME1 2 CPUs 10 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMME1 P1 DIMMF1 CPU2 P2 DIMMB1 P2 DIMMA1 P2 DIMMD1 P2 DIMME1 2 CPUs 12 DIMMs CPU1 P1 DIMMC1 P1 D...

Page 40: ...DRAM1 DCPMM DRAM1 DCPMM DCPMM DRAM1 DCPMM DRAM1 DRAM1 2 2 1 MM DRAM1 DRAM1 DCPMM DRAM1 DCPMM DCPMM DRAM1 DCPMM DRAM1 DRAM1 2 2 1 AD MM DRAM3 DRAM3 DCPMM DRAM3 DCPMM DCPMM DRAM3 DCPMM DRAM3 DRAM3 2 2 1...

Page 41: ...the 82xx 62xx 52xx 42xx platform For each individual population please use the same DDR4 DIMM in all slots For each individual population sockets are normally symmetric with exceptions for 1 DCPMM per...

Page 42: ...LED1 JP2 JSD2 JSD1 SP1 FAN7 FAN8 FAN5 FAN6 FAN3 FAN4 FAN1 FAN2 JP6 JP5 JWD1 JPB1 JPG1 JPQAT JPL1 JPME1 JP1 JPME2 PSU2 PSU1 JUIDB2 JL1 JBT1 JSDCARD1 JTPM1 JP_BSCAN_BMC M 2 JIPMB1 CN6 CN5 CN4 M 2 B37 A...

Page 43: ...memory is powered by a lithium battery residing on the motherboard Replacing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers th...

Page 44: ...inux RHEL 7 4 Command output in this section may be abbreviated for easier reading Additional notes are added with marking As NVMe SSD events are generally associated with their dev entries in Linux t...

Page 45: ...through the Locate function in the BMC GUI as shown above When located the slot LED will blink RED 3 Prepare the target NVMe SSD for hot removal On the BMC GUI once the target NVMe SSD has been corre...

Page 46: ...k that the dev entry has been removed Execute the dmesg command and check the related messages The slot LED should become solid GREEN After confirming that the target NVMe SSD has been removed from by...

Page 47: ...Additional notes are added with marking Windows generally reports NVMe SSD events associated with a disk or harddisk number In this section a method is shown how to correlate an NVMe SSD s slot number...

Page 48: ...able The selected Intel SSD contains current firmware as of this tool release Index 4 ModelNumber INTEL SSDPERKX040T7 Vendor Model ProductFamily Intel SSD DC P4500 Series SerialNumber BTLF736500FD4P0S...

Page 49: ...nce the GUI indicates that the NVMe SSD has been rejected successfully the target would have been removed from the OS Please wait for the target SSD to be fully removed from host by checking Its Disk...

Page 50: ...permicro com products system 1U 1029 SYS 1029P NR32R cfm External References Intel SSD Data Center Tool information and downloads https downloadcenter intel com download 27863 v t Cable Connections IP...

Page 51: ...ve bay numbering identification see Figure 3 6 on the the next page Each sled has two levers Pull these levers outward to unlock the sled Top View Pull Pull Sled 1 Sled 2 1 Figure 3 5 Removing the Sle...

Page 52: ...SuperServer 1029P N32R User s Manual 52 Figure 3 6 NVMe Drive Bay Identification...

Page 53: ...or end toward the rear of the carrier Insert the drive at an angle as shown in Figure 3 7 Verify that the mounting holes on the drive align with the mounting holes on the carrier 3 Swing both locking...

Page 54: ...move the drive carrier and its drive 3 Release and swing open the locking latches on the side of the drive carrier 4 Remove the drive from its carrier at an angle as shown in Figure 3 10 Figure 3 10 R...

Page 55: ...CPLD design architecture Slot is the slot number on which the NVMe drives are mounted Replacing the Drive 1 Insert the replacement drive 2 IPMI Server Health NVMe SSD 3 Select Device Group and slot a...

Page 56: ...over while the system is still running to determine which of the fans has failed Then power down the system before replacing a fan Replacing System Fans 1 After determining which fan has failed turn o...

Page 57: ...at the power supply is operating Changing the Power Supply 1 Determine which power supply needs to be replaced and unplug the power cord to that module 2 Push the release tab on the back of the power...

Page 58: ...er supply SMCI Proprietary Power PSU1 PSU2 8 pin Processor Power JPWR1 JPWR2 SMCI Proprietary Power Connectors Two SMCI proprietary Power Supply Unit connectors located at PSU1 PSU2 provide main power...

Page 59: ...LAN2 JLAN1 LE1 LED4 LED3 JCOM2 JRK1 BT1 JIPMILAN JPWR1 JPWR2 JUSB1 LEDM1 LED1 JP2 JSD2 JSD1 SP1 FAN7 FAN8 FAN5 FAN6 FAN3 FAN4 FAN1 FAN2 JP6 JP5 JWD1 JPB1 JPQAT JPME1 JP1 JPME2 PSU2 PSU1 JUIDB2 JL1 JBT...

Page 60: ...nel located at JUSB1 Back Panel USB 12 13 3 0 Pin Definitions Pin Definition Pin Definition A1 VBUS B1 Power A2 D B2 USB_N A3 D B3 USB_P A4 GND B4 GND A5 Stda_SSRX B5 USB3_RN A6 Stda_SSRX B6 USB3_RP A...

Page 61: ...1 FAN7 FAN8 FAN5 FAN6 FAN3 FAN4 FAN1 FAN2 JP6 JP5 JWD1 JPB1 JPQAT JPME1 JP1 JPME2 PSU2 PSU1 JUIDB2 JL1 JBT1 JSDCARD1 JTPM1 JP_BSCAN_BMC M 2 JIPMB1 CN6 CN5 CN4 M 2 B37 A37 A1 B1 A1 A37 CN3 CN2 CN1 J30...

Page 62: ...ger Refer to the table below for pin definitions Power Button Pin Definitions JF1 Pins Definition 1 Signal 2 Ground Reset Button The Reset Button connection is located on pins 3 and 4 of JF1 Attach it...

Page 63: ...ice Blinking blue 300 msec Remote UID is on Use this function to identify a unit from a remote location that might be in need of service NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Controller LED co...

Page 64: ...0 connector is a security device that supports encryption and authentication in hard drives It allows the motherboard to deny access if the TPM associated with the hard drive is not installed in the s...

Page 65: ...2 Slots The X11DPS RE motherboard has two PCI E hybrid M 2 slots J30 SLOT1 and J31 SLOT2 M 2 was formerly Next Generation Form Factor NGFF and serves to replace mini PCI E M 2 allows for a variety of...

Page 66: ...Supermicro SuperDOMs are backward compatible with regular SATA HDDs or SATA DOMs that need external power cables SATA 3 0 Port Pin Definitions Pin Signal 1 Ground 2 SATA_TXP 3 SATA_TXN 4 Ground 5 SAT...

Page 67: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Page 68: ...ME Firmware Recovery mode which will limit resource allocation for essential system operation only in order to maintain normal power operation and management In the single operation mode online upgra...

Page 69: ...king Active IPMI LAN Link LED Activity LED BMC Heartbeat LED LEDM1 is the BMC heartbeat LED When the LED is blinking green BMC is functioning normally See the table below for the LED status BMC Heartb...

Page 70: ...ear UID LED indicator at LED1 is located near the UID switch on the I O back panel This UID indicator provides easy identification of a system unit that may need service UID LED LED Indicator LED Colo...

Page 71: ...on the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper driver fi...

Page 72: ...Figure 5 1 should appear Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual driver...

Page 73: ...nagement Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP and SMTP...

Page 74: ...Configuration Use IPMI to update the configuration of the PCIe switches 1 Log into the IPMI The default Username and Password are ADMIN ADMIN 2 Under the Maintenance tab select PCIE Switch FW Update...

Page 75: ...Chapter 5 Software 75 4 Click OK to confirm Both switches are updated consecutively and the progress is reported 5 Click OK to finish...

Page 76: ...the BMC Firmware Use IPMI to update the BMC firmware 1 Log into the IPMI The default Username and Password are ADMIN ADMIN 2 Under the Maintenance tab select Firmware Update 3 Click the Enter Update M...

Page 77: ...Click Choose File select the configuration file then click the Upload Firmware button 5 Clear all check box options and click the Start Upgrade button 6 Click OK to confirm and wait The system reboots...

Page 78: ...ed such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options c...

Page 79: ...Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YYYY form...

Page 80: ...eature allows you to specify the boot sequence from the list of available USB drives A device that is in parenthesis has been disabled in the corresponding type menu Network Drives This feature allows...

Page 81: ...M timing setting may make the system unstable When this occurs revert to the default to the manufacture default settings Boot Feature Quiet Boot Use this feature to select the screen between displayin...

Page 82: ...Postponed Re try Boot When EFI Expansible Firmware Interface Boot is selected the system BIOS will automatically reboot the system from an EFI boot device after an initial boot failure Select Legacy B...

Page 83: ...Ratio Microcode Revision L1 Cache RAM L2 Cache RAM L3 Cache RAM Processor 0 Version Processor 1 Version Hyper Threading ALL Select Enable to use Intel Hyper Threading Technology to enhance CPU perform...

Page 84: ...er Available when supported by the CPU If this feature is set to Enable the hardware prefetcher will prefetch streams of data and instructions from the main memory to the Level 2 L2 cache to improve C...

Page 85: ...r Performance Tuning is set to BIOS Controls EPB This feature allows the user to set the desired processor power use policy for the machine by prioritizing system performance or energy savings Selecti...

Page 86: ...State Select Enable to support Autonomous Core C State control which will allow the processor core to control its C State setting automatically and independently The options are Disable and Enable CPU...

Page 87: ...conflict The options are Topology Precedence and Feature Precedence Link L0p Enable Select Enable to enable Link L0p The options are Disable Enable and Auto Link L1 Enable Select Enable to enable Link...

Page 88: ...force POR Select POR to enforce POR restrictions for DDR4 memory frequency and voltage programming The options are POR and Disable Memory Frequency Use this feature to set the maximum memory frequency...

Page 89: ...re Disable Mirror Mode 1LM and Mirror Mode 2LM Memory Rank Sparing Select Enable to support memory rank sparing to optimize memory performance The options are Disable and Enable Note This item will no...

Page 90: ...memory behind the IO hub will be scrubbed every day The options are Disable and Enable Patrol Scrub Interval Use this item to specify the number of hours between 0 to 24 required for the system to com...

Page 91: ...designate maximum packet size of 128 or 256 Options are Auto 128 and 256 Auto is enabled by default IOAT Configuration Disable TPH TLP Processing Hint TPH is used for data tagging with a destination I...

Page 92: ...s are Enable and Disable Posted Interrupt Select Enable to support VT_D Posted Interrupt which will allow external interrupts to be sent directly from a direct assigned device to a client machine in n...

Page 93: ...n Isoch Use this feature to maintain setting coherency between processors or other devices Select Enable for the Non Iscoh VT d engine to pass through DMA to enhance system performance The options are...

Page 94: ...ot support legacy USB devices The options are Disabled and Enabled Port 61h Bit 4 Emulation Select Enabled to enable the emulation of Port 61h but 4 toggling in SMM System Management Mode The options...

Page 95: ...roller should be used for system boot The options are None SATA Controller sSATA Controller and Both Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages...

Page 96: ...word in the OS The options are Enable and Disable SATA sSATA RAID Boot Select Available when the item Configure SATA as is set to RAID This feature allows the user to decide which controller should be...

Page 97: ...Enabled SR IOV Support Available if the system supports Single Root Virtualization Select Enabled for Single Root IO Virtualization support The options are Disabled and Enabled MMIO High Base Use thi...

Page 98: ...e Legacy and EFI Onboard Video Option ROM Use this feature to select the Onboard Video Option ROM type The options are Disabled Legacy and EFI Onboard LAN1 Option ROM Use this feature to select the ty...

Page 99: ...l be checked The default is 1 Super IO Configuration Super IO Chip AST2500 Serial Port 1 Configuration Serial Port 1 Select Enabled to enable the onboard serial port specified by the user The options...

Page 100: ...7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Attribute Select SOL to use COM Port 2 as a Serial_Over_LAN SOL port for console redirection The options are SOL and COM Serial Port Con...

Page 101: ...our data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if...

Page 102: ...configuration Console Redirection Settings for SOL Use this feature to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Terminal...

Page 103: ...direction to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start data sending when the receiving buffer i...

Page 104: ...Console Redirection The options are Disabled and Enabled If the item above set to Enabled the following items will become available for user s configuration Console Redirection Settings EMS Out of Ba...

Page 105: ...em performance The options are Disabled and Enabled WHEA Support Select Enabled to support the Windows Hardware Error Architecture WHEA platform and provide a common infrastructure for the system to h...

Page 106: ...Trusted Computing Available when a TPM device is installed and detected by the BIOS When a TPM Trusted Platform Module device is detected in your machine the following information will be displayed TP...

Page 107: ...cluded in the list of public keys During system boot the platform firmware uses this trusted public key to verify a digital signature in an attempt to manage and control the security of the platform f...

Page 108: ...nabled to enable Intel Trusted Execution Technology TXT support to enhance system security and data integrity The options are Disabled and Enabled Note 1 If the option for this item TXT Support is set...

Page 109: ...Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Enabled and Disabled MECI Multiple Event Count Increment Enter the increment value for the multiple...

Page 110: ...e displayed Date Time Error Code Severity 6 5 IPMI Use this feature to configure Intelligent Platform Management Interface IPMI settings When you select this submenu and press the Enter key the follow...

Page 111: ...allows the user to determine whether the BIOS will log EFI Status Cods error code only progress code only or both The optioins are Disabled Both Error code and Progress code Note After making changes...

Page 112: ...Address This item displays the Gateway IP address for this computer This should be in decimal and in dotted quad form i e 172 31 0 1 VLAN Enabling this item displays the virtual LAN settings The opti...

Page 113: ...required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long User Password Press Enter to create a new or change an existing User password Pas...

Page 114: ...options are Disabled and Enabled Key Management Provision Factory Defaults Select Enabled to install all manufacturer default keys for the following system security settings The options are Disabled a...

Page 115: ...as Authorized Signatures for the system This set of values also indicate the size the keys numbers and the key source of the Authorized Signatures The options are Save to File Set New Append and Eras...

Page 116: ...rt The options are Disabled and Enabled Fixed Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boot Press Enter on each entry from top to bottom...

Page 117: ...priority list Delete Boot Option Use this item to remove an EFI boot option from the boot priority list Delete Driver Option This feature allows the user to add a new boot option to the boot priority...

Page 118: ...puter Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup util...

Page 119: ...t this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature sele...

Page 120: ...to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs The fatal errors are usually communicated through repeated patterns of a...

Page 121: ...com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnost...

Page 122: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...

Page 123: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Page 124: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...

Page 125: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Page 126: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...

Page 127: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Page 128: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...

Page 129: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Page 130: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...

Page 131: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Page 132: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All co...

Page 133: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Page 134: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...

Page 135: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Page 136: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...

Page 137: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Page 138: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...

Page 139: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Page 140: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto ut...

Page 141: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Page 142: ...tel C627 controller Drive Bays Up to thirty two 32 2 5 internal drive bays PCI Expansion Slots 2 PCI E 3 0 x32 Tray cable connector interface 2 PCI E 3 0 x16 slots with riser card support Motherboard...

Page 143: ...and GB17625 1 2012 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Delegated Di...

Page 144: ...ds off management to a computer during system boot D 2 Recovering the UEFI BIOS Image A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image The recovery bloc...

Page 145: ...ed several minutes to locate the SUPER ROM file if the media size becomes too large due to the huge volumes of folders and files stored in the device To perform UEFI BIOS recovery using a USB attached...

Page 146: ...USB drive and reset the system when the following screen appears 3 After locating the healthy BIOS binary image the system will enter the BIOS Recovery menu as shown below Note At this point you may...

Page 147: ...ring system boot to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI...

Page 148: ...h BIOSname at the prompt to start the BIOS update process 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power s...

Page 149: ...id Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise In...

Page 150: ...JRK1 The key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd part...

Page 151: ...uration North Bridge IIO Configuration Intel VMD Technology CPU1 CPU2 5 Enable the VMD according to the following rules For U 2 NVMe enable all the sub items under each PStack based on the your model...

Page 152: ...ID on CPU All Intel VMD Controllers Create RAID Volume 9 Set Name 10 Set RAID Level 11 If cross controller RAID is required select Enable RAID spanned over VMD Controller as shown in Figure E 4 12 Sel...

Page 153: ...ation at link 1 below Hot unplug 1 Prevent devices from being re detected during rescan esxcli storage core claiming autoclaim enabled false 2 Unmount the VMFS volumes on the device Check 2 for detail...

Reviews: