Chapter 2: Server Installation
2-9
Figure 2-6. Installing into a Rack
Ball-Bearing
Shuttle
Standard Chassis Installation
Installing the Chassis into a Rack (Figure 2-6)
1. Confi rm that the inner rails are properly installed on the chassis.
2. Confi rm that the outer rails are correctly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the
ball-bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure
even on both sides, until the locking tab of the inner rail clicks into the front of
the middle rail, locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis
all the way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles
to the front of the rack.
Note:
The fi gure below is for illustration purposes only. Always install servers to
the bottom of the rack fi rst.
Summary of Contents for Supero SUPERSERVER 2027PR-DC1FR
Page 1: ...SUPERSERVER 2027PR DC1R 2027PR DC1FR 2027PR DC1TR SUPER USER S MANUAL Revision 1 0...
Page 5: ...v SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL Notes...
Page 10: ...x Notes SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL...
Page 34: ...SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL 3 4 Notes...
Page 84: ...5 30 SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL Notes...
Page 102: ...6 18 SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL Notes...
Page 140: ...A 2 SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL Notes...