Page 1: ...SUPERSERVER 2027PR DC1R 2027PR DC1FR 2027PR DC1TR SUPER USER S MANUAL Revision 1 0...

Page 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Page 3: ...DC1FR DC1TR servers and their associated serverboards for each of their unique options are listed in the table below SUPERSERVER 2027PR DC1R DC1FR DC1TR Model Variations Server Model X9DRT Serverboard...

Page 4: ...vides detailed information on the X9DRT P PIBF PT serverboard including the locations and functions of connections headers and jumpers Refer to this chapter when adding or removing processors or main...

Page 5: ...v SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL Notes...

Page 6: ...1 4 I O Ports 1 4 Cooling System 1 4 Air Shrouds 1 5 Mounting Rails 1 5 1 4 Advanced Power Management 1 5 Intel Intelligent Power Node Manager IPNM 1 5 Manageability Engine ME 1 5 1 4 Contacting Super...

Page 7: ...rive Bay Setup 2 12 Chapter 3 System Interface 3 1 Overview 3 1 3 2 Control Panel Buttons 3 2 Power 3 2 UID 3 2 3 3 Control Panel LEDs 3 2 NIC 3 2 Information LED 3 3 4 4 Drive Carrier LEDs 3 3 Chapte...

Page 8: ...ector Definitions 5 16 5 9 Jumper Settings 5 20 Explanation of Jumpers 5 20 5 10 Onboard Indicators 5 23 5 11 PCI Express and Serial ATA Connections 5 25 5 12 Installing Software 5 26 SuperDoctor 5 5...

Page 9: ...the Drive Bays 6 14 6 12 Power Supply 6 17 Power Supply Replacement 6 17 Chapter 7 BIOS Starting BIOS Setup Utility 7 1 How To Change the Configuration Data 7 1 Starting the Setup Utility 7 2 7 1 Mai...

Page 10: ...x Notes SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL...

Page 11: ...passive CPU heat sinks w narrow ILM SNK P0048PS SAS SATA Backplane One 1 Twin backplane supporting 24 SATA HDD 2 5 with hot swapping BPN SAS3 217HD Two 2 LSI 3108 SAS SATA 12 Gbps supporting up to 8 S...

Page 12: ...to 8 GT s per QPI Memory The X9DRT P PIBF PT has sixteen 16 DIMM slots supporting up to 1 TB of 240 pin Registered RDIMM Load Reduced LRDIMM ECC or Unbuffered UDIMM ECC Non ECC DDR3 1866 1600 1333 10...

Page 13: ...M450R BMC Baseboard Management Control chip supports LAN 2 0 Onboard Controllers Ports A Mellonox InfiniBand connector is located on the 2027PR DC1FR serverboard The color coded I O ports on all serve...

Page 14: ...erating system you use must have RAID support to enable the hot swap capability of the drives Front Control Panel SC217 models include four front panels on the handles of the chassis which control eac...

Page 15: ...ment Intel Intelligent Power Node Manager IPNM The Intel Intelligent Power Node Manager IPNM provides your system with real time thermal control and power management for maximum energy efficiency Alth...

Page 16: ...H F E Socket 0 Socket 1 1 1 1 1 P0 P0 P1 P1 VGA BMC VGA CONN WPCM450 DDR2 PHY1 LAN RTL8201F SPI UM1 PCI E x8 GEN3 Gen3 x16 Gen3 x8 x8 HOTSWAP INTERFACE SATA3 0 SATA3 1 SATA2 3 SATA2 4 SATA2 5 PORT1 PO...

Page 17: ...Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro n...

Page 18: ...top when a node is fully installed If too much force is used when inserting a node this pin may break off Take care to slowly slide a node in until you hear the click of the locking tab seating itself...

Page 19: ...ged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the 2027PR DC1R DC1FR D...

Page 20: ...ingle rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component...

Page 21: ...i unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipme...

Page 22: ...allation instructions that came with the rack unit you are using NOTE This rail will fit a rack between 26 5 and 36 4 deep Warning Do not pick up the server with the front handles They are designed to...

Page 23: ...nstallation 2 5 Figure 2 1 Identifying the Outer Rail Middle Rail and Inner Rails Left Rail Assembly Shown Inner Rail Rail Assembly Shown with Rails Retracted This Side Faces Outward Locking Tab Middl...

Page 24: ...pulled out for servicing Releasing the Inner Rail Use the procedure below to release the inner rails from the outer rails Releasing Inner Rail from the Outer Rails Figure 2 2 1 Identify the left and r...

Page 25: ...the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the rail clicks into the loc...

Page 26: ...he middle rail back into the outer rail 3 Hang the hooks of the front of the outer rail onto the slots on the front of the rack If necessary use screws to secure the outer rails to the rack as illustr...

Page 27: ...middle rail 4 Align the chassis inner rails with the front of the middle rails 5 Slide the inner rails on the chassis into the middle rails keeping the pressure even on both sides until the locking ta...

Page 28: ...1 Uplug the AC power cord from any external power source 2 Remove the two screws which secure the top cover onto the chassis as shown above 3 Lift the top cover up and off the chassis 4 Peel off the...

Page 29: ...r system may have come with system memory already installed Make sure all DIMMs are fully seated in their slots For details on adding system memory refer to Chapter 5 3 If desired you can install add...

Page 30: ...and out of the chassis In addition if you are using a front bezel make sure the bezel s filter is replaced periodically 2 Except for brief periods while swapping hard drives do not operate the server...

Page 31: ...the drive carriers to keep you constantly informed of the overall status of the system SC217 models include four front panels on the handles of the chassis which control each of the systems This chapt...

Page 32: ...power but keeps standby power supplied to the system The power button has a built in LED which will turn green when the power is on UID When used with a UID compatible motherboard the UID button is us...

Page 33: ...fail you should be notified by your system management software SCSI Drives This chassis does not support SCSI drives at this time Information LED See the following table for the status shown by this...

Page 34: ...SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL 3 4 Notes...

Page 35: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Page 36: ...er equipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a e...

Page 37: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Page 38: ...em Anschlie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant...

Page 39: ...erstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuito...

Page 40: ...ower and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 250V 20A Waarschuwing Dit product is afhankelijk van de kort...

Page 41: ...tado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sourc...

Page 42: ...uipment Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reem...

Page 43: ...eug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una d...

Page 44: ...ith the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden...

Page 45: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Page 46: ...icherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar p...

Page 47: ...System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero...

Page 48: ...Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is V...

Page 49: ...onal laws and regulations Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriqu...

Page 50: ...le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning The fans might...

Page 51: ...tfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del v...

Page 52: ...UL CSA UL CSA Supermicro UL CSA UL CSA Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter...

Page 53: ...s dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres c...

Page 54: ...gewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik va...

Page 55: ...nding keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a...

Page 56: ...Blue 8 UID LED on the motherboard 9 UID Switch 2 1 6 3 4 7 8 9 5 2 Connecting Cables Now that the processors are installed the next step is to connect the cables to the serverboard Connecting Data Cab...

Page 57: ...ely use only an Intel certified multi directional heatsink Avoid placing direct pressure to the top of the processor package Install the processor into the CPU socket before installing the heatsink Re...

Page 58: ...nd edges will fit the socket OPEN1st OPEN1st IMPORTANT Caution You can only install the CPU into the socket in one direction Make sure that the CPU is properly inserted into the socket before closing...

Page 59: ...sure the locking mechanism on the Close 1st lever catches the lip of the load plate Close and lock the Close 1st lever OPEN1st OPEN1st Push down and lock the lever labeled Close 1st Engage the lip of...

Page 60: ...are aligned with those on the Serverboard s and the Heatsink Bracket underneath Make sure the heatsink is placed so that the fins of the heatsink are in the direction of the airflow in your system 3...

Page 61: ...tsink screws from the motherboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 On...

Page 62: ...Memory Sizes RDIMM 1GB 2GB 4GB 8GB 16GB and 32GB 1 35V 1 5V UDIMM 512MB 1GB 2GB 4GB and 8GB LRDIMM 8GB 16GB 32GB and 64GB It is highly recommended that you remove the power cord from the system befor...

Page 63: ...P2 DIMME2 P2 DIMM F2 P2 DIMMG2 P2 DIMMH2 To Install Insert module vertically and press down until it snaps into place Pay attention to the alignment notch at the bottom To Remove Use your thumbs to ge...

Page 64: ...C1 P1 DIMMD1 P2 DIMME1 P2 DIMMF1 P2 DIMMG1 P2 DIMMH1 P1 DIMMA2 P1 DIMMB2 P1 DIMMC2 P1 DIMMD2 P2 DIMME2 P2 DIMMF2 P2 DIMMG2 P2 DIMMH2 Installing UDIMM ECC Non ECC Memory Intel E5 2600 V2 Series Process...

Page 65: ...2GB 4GB 8GB 1066 1333 1600 1066 1333 1600 1866 1066 1333 1600 1066 1333 1600 1866 1066 1333 1600 1066 1333 1600 1866 SRx4 2GB 4GB 8GB 1066 1333 1600 1066 1333 1600 1866 1066 1333 1600 1066 1333 1600...

Page 66: ...k properly please install DIMM modules of the same type same speed and same operating frequency on the motherboard Mixing of RDIMMs UDIMMs or LRDIMMs is not allowed Do not install both ECC and Non ECC...

Page 67: ...3 FAN4 JSD1 LEB2 LEB1 LEM1 LE3 LE1 J10 JTPM1 JBT1 JIPMB1 IPMI CODE BAR CODE MAC CODE IPMI LAN CPU1 SLOT2 PCI E 3 0 X8 VGA P1 DIMMA1 P1 DIMMA2 P1 DIMMD2 P1 DIMMD1 CPU1 SLOT1 PCI E 3 0 X16 P1 DIMMB2 P1...

Page 68: ...t username is ADMIN and password is ADMIN For BMC best practices please refer to http www supermicro com products nfo files IPMI Best_Practices_BMC_Security pdf X9DRT P PIBF PT Quick Reference Jumper...

Page 69: ...JLAN1 10_Gigabit Ethernet LAN Port 1 by the Intel X540 chip for X9DRT PT only JSD1 SATA DOM Device_on_Module Power Connector JTPM1 TPM Trust Platform Module Port 80 Header I SATA0 SATA 0 Connector sup...

Page 70: ...Serial Bus Ports Two Universal Serial Bus ports USB 0 1 are located on the I O back panel In addition a USB header located next to the LAN controller provides two front accessible USB connections USB...

Page 71: ...Ground 8 TD3 17 Ground 9 TD3 18 Ground Note NC indicates no connection Unit Identifier Switches A Unit Identifier UID switch is located at UIDSW2 on the I O panel and a UID LED indicator is located at...

Page 72: ...9 Module Reset 10 3 3V Power Supply Receiver 11 2 wire Serial Interface Clock 12 2 wire Serial Interface Data 13 Ground 14 Receiver Non Inverted Data Output 15 Receiver Inverted Data Output 16 Ground...

Page 73: ...em Management Bus header for the IPMI slot is located at JIPMB1 Connect an appropriate cable here to use the IPMB I2 C connection on your system SMB Header JIPMB1 Pin Definitions Pin Definition 1 Data...

Page 74: ...JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power d...

Page 75: ...ins 1 2 Enabled Default Pins 2 3 Disabled BMC Enable JPB1 Jumper Settings Jumper Setting Definition Pins 1 2 Enable Default Pins 2 3 Normal GLAN Enable Disable JPL1 enables or disables the LAN Port 1...

Page 76: ...e right for jumper settings Manufacture Mode Select Close Pin 2 and Pin 3 of Jumper JPME2 to bypass SPI flash security and force the system to operate in the Manufacture Mode allowing the user to flas...

Page 77: ...Right Active IPMI LAN Activity LED Link LED LAN LEDs The Ethernet LAN port is located on the IO Backplane on the motherboard Each LAN port has two LEDs The Yellow LED indicates activity The Link LED o...

Page 78: ...on the motherboard This LED indicates the status of hard drive activities or SATA activities Also see the layout below for the LED locations Onboard Power LED An Onboard Power LED is located at LE1 o...

Page 79: ...r the SMC Proprietary add on card Refer to the layout below for the locations SATA Port A Serial ATA port I SATA0 is located on the motherboard This port provides serial link signal support which is f...

Page 80: ...if preferred Another option is to go to the Supermicro Website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utiliti...

Page 81: ...em voltages system power consumption fan speed and provides alerts via email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with...

Page 82: ...Doctor 5 Interface Display Screen Remote Control Note The SuperDoctor 5 program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products nfo sms_sd5 cfm For...

Page 83: ...urer CR2032 Dispose of used batteries according to the manufacturer s instructions Figure 5 9 Installing the Onboard Battery Please handle used batteries carefully Do not damage the battery in any way...

Page 84: ...5 30 SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL Notes...

Page 85: ...ery carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded met...

Page 86: ...supplies remove the cords from both power supplies 4 Disconnect the cord from the power strip or wall outlet 6 3 Control Panel The control panel is located on the front of the chassis The LEDs inform...

Page 87: ...r onto the chassis as shown above 3 Lift the top cover up and off the chassis 4 Peel off the protective film covering the top cover and the top of the chassis 5 Check that all ventilation openings on...

Page 88: ...trations below Installing an Air Shroud Figure 6 3 1 Make sure that the motherboard expansion card if applicable and all components are properly installed in each motherboard node 2 Place the first ai...

Page 89: ...airflow through the chassis Pull all excess cabling out of the airflow path or use shorter cables 4 The control panel LEDs inform you of system status See Chapter 3 System Interface for details on the...

Page 90: ...is 4 Remove the failed fan s power cable from the backplane 5 Lift the fan housing up and out of the chassis 6 Push the fan up from the bottom and out of the top of the housing 7 Place the replacement...

Page 91: ...ckplane Removing the Backplane from the Chassis 1 Power down and unplug the system from any power source 2 Remove the chassis cover 3 Disconnect the cabling to the backplane 4 Remove all of the hard d...

Page 92: ...bar located on the floor of the chassis indicated by the arrows below Figure 6 7 8 Gently ease the backplane up and out of the chassis at a slight angle Figure 6 8 Figure 6 7 Loosening the Spring Bar...

Page 93: ...the backplane into the chassis at a slight angle pushing it up against the side of the chassis 4 Ease the backplane forward against the front of the chassis This will aid in the alignment of the mount...

Page 94: ...ffs Standoffs prevent short circuits by creating space between the motherboard and the chassis surface The SC217 chassis includes permanent standoffs in locations used by the motherboards These stando...

Page 95: ...gning the standoffs with the motherboard 5 Secure the motherboard to the node drawer using the rounded Phillips head screws included for this purpose Do not exceed eight inch pounds of torque when tig...

Page 96: ...hem aside for later use 4 Remove the daughter card and spacer plate from the motherboard drawer 5 Set the spacer plate aside for later use Installing the Daughter Card 1 Make sure the motherboard has...

Page 97: ...nsion Card The SC217 chassis supports expansion cards Riser cards are used to mount the expansion cards The SC217HD model accepts two low profile expansion cards per node for a total of four in the ch...

Page 98: ...river SAS LSI LSI_SAS_EmbMRAID_SWUG pdf and Supermicro s web site for additional inmformation http www supermicro com support manuals The SC217 chassis contains four individual motherboards in separat...

Page 99: ...1 Press the release button on the drive tray This extends the drive bay handle 2 Use the handle to pull the drive out of the chassis Figure 6 17 Removing Hard Drive 1 1 1 2 Cauton Except for short per...

Page 100: ...e carrier 3 Install a new drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier 4 Secure the hard drive by tightening all fo...

Page 101: ...s two redundant power supplies In the unlikely event that the power supply unit needs to be replaced one power supply can be removed without powering down the system Replacement units can be ordered d...

Page 102: ...6 18 SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL Notes...

Page 103: ...erved for informational text When an option is selected in the left frame it is highlighted in white Often informational text will accompany it Note The AMI BIOS has default informational messages bui...

Page 104: ...Do not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall the manufacturer be liable for direct indirect...

Page 105: ...ey to move between fields The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermi...

Page 106: ...T messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Enabled and Disabled AddOn ROM Display Mode Use this feature to set the display mode for the Optio...

Page 107: ...boot drive The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog timer will allow the system to automatically reboot when a non recoverable...

Page 108: ...ding Technology Intel VT x Technology Intel SMX Technology L1 Data Cache L1 Code Cache L2 Cache L3 Cache CPU Speed This item displays the speed of the CPU installed in Socket 1 or Socket 2 64 bit This...

Page 109: ...overwhelm the processor or damage the system during an attack The default is Enabled Refer to Intel and Microsoft Web sites for more information Intel AES NI Select Enable to use the Intel Advanced En...

Page 110: ...ntory_Number PPIN support which will allow the BIOS setup returns a 64 bit ID number via the PPIN MSR Magnetic Stripe Reader The options are Enabled and Disabled CPU Power Management Configuration Thi...

Page 111: ...C State package register The options are C0 C2 C6 and No Limit Energy Performance Bias Use this feature to select an appropriate fan setting to achieve maximum system performance with maximum cooling...

Page 112: ...hine Monitor through the DMAR ACPI Tables This feature offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data...

Page 113: ...ion 2 support for the port specified Select GEN3 to enable PCI Exp Generation 3 support for the port specified The options are GEN1 GEN2 and GEN3 IIO 2 PCIe Port Bifurcation Control This submenu confi...

Page 114: ...information Current Memory Mode This item displays the current memory mode Current Memory Speed This item displays the current memory speed Mirroring This item displays if memory mirroring is supporte...

Page 115: ...he options are Auto 1 Way 2 Way 3 Way and 4 Way Rank Interleaving This feature allows the user to select a rank memory interleaving method The options are Auto 1 Way 2 Way 4 Way and 8 Way Patrol Scrub...

Page 116: ...nboard memory to enhance memory and system performance The options are Auto Enabled and Disabled South Bridge Configuration This feature allows the user to configure the settings for the Intel PCH chi...

Page 117: ...ange will be claimed by the EHCI driver The options are Disabled and Enabled SATA Configuration When this submenu is selected the AMI BIOS automatically detects the presence of the SATA Devices and di...

Page 118: ...s are displayed Serial ATA Port 0 Port 5 This item displays the information detected on the installed SATA drives on the particular SATA port Model number of drive and capacity Software Preserve Suppo...

Page 119: ...sing the LSI controller The options are Intel and LSI SATA RAID Option ROM UEFI Driver Available if the item above SATA Mode Select is set to AHCI or RAID Select Enabled to use the SATA RAID Option RO...

Page 120: ...ERR Generation Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus Signal Error Event The options are Enabled and Disabled Maximum Payload Select Auto to allow the system BIO...

Page 121: ...Onboard LAN2 Option ROM Select Enabled to enable the onboard LAN1 LAN2 Option ROM This is to boot the computer using a network device The default setting for LAN1 Option ROM is Enabled and the defaul...

Page 122: ...ort specified The options are Normal and High Speed SOL Serial_Over_LAN Configuration SOL Serial Port Select Enabled to enable a serial port specified by the user The options are Enabled and Disabled...

Page 123: ...emote computer used by the user Terminal Type This feature allows the user to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII Character set Select VT100...

Page 124: ...w control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data whe...

Page 125: ...ter will exchange data with the client computer which is the remote computer used by the user Out of Band Management Port The feature selects a serial port used by the Microsoft Windows Emergency Mana...

Page 126: ...PU caches and stop executing instructions Power to the CPU s and RAM is maintained but RAM is refreshed Select Suspend Disabled to use power reduced mode Power will only be supplied to limited compone...

Page 127: ...his item to schedule an operation for the security device The options are None Enable Take Ownership Disable Take Ownership and TPM Clear Note During restart the computer will reboot in order to execu...

Page 128: ...Dependencies This feature displays the features that need to be enabled for the Intel Trusted Execution Technology to work properly in the system VT d Support Intel Virtualization Technology with Dire...

Page 129: ...he current port The options are AutoNeg 10Mbps Half 10Mbps Full 100Mbps Half and 100Mbps full Wake on LAN Select enabled to wake the system with a magic packet The options are Enabled and Disabled Bli...

Page 130: ...nabling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Se...

Page 131: ...e limit when the SMBIOS event log is full Select Do Nothing for the system to do nothing when the SMBIOS event log is full The options are Do Nothing and Erase Immediately SMBIOS Event Log Standard Se...

Page 132: ...number and status System Event Log SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to era...

Page 133: ...nfiguration This feature allows the BIOS to implement any IP MAC address changes at the next system boot If the option is set to Yes any changes made to the settings below will take effect when the sy...

Page 134: ...ter belongs to The value of each three digit number separated by dots should not exceed 255 Station MAC Address This item displays the Station MAC address for this computer Mac addresses are 6 two dig...

Page 135: ...BBS Priorities Available when a device is installed in this drive 1st Device 2nd Device USB Hard Disk Drive BBS Priorities Available when a device is installed in this drive 1st Device Network Device...

Page 136: ...ollowing security settings for the system Password Check Use this feature to determine when a password entry is required Select Setup to require the password only when entering setup Select Always to...

Page 137: ...to exit the BIOS setup without saving select Yes to quit BIOS without saving the changes or select No to quit the BIOS and save changes Save Changes and Reset When you have completed the system config...

Page 138: ...you if you want to load optimized defaults select Yes to load the optimized default settings or select No to abandon optimized defaults Save as User Defaults Select this feature and press Enter to sav...

Page 139: ...communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed with the excep...

Page 140: ...A 2 SUPERSERVER 2027PR DC1R DC1FR DC1TR USER S MANUAL Notes...

Page 141: ...SDRAM in 1 GB 2 GB 4 GB 8 GB 16 GB or 32 GB size sizes of 1 5V or 1 35V voltages Note refer to Section 5 5 for details on installation Note Check the Supermicro website www supermicro com for the lat...

Page 142: ...o 95 F Non operating Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Note The system power supplies are re...

Page 143: ...B 3 Appendix B System Specifications Notes...

Page 144: ...e to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell...