2-10
H8DSL-HTi User's Manual
Overheat/Fan Fail LED
Connect an LED to the OH connection
on pins 7 and 8 of JF1 to provide ad-
vanced warning of chassis overheat-
ing. Refer to the table on the right for
pin defi nitions.
NIC1 LED
The NIC1 (Network Interface Control-
ler) LED connection is located on pins
11 and 12 of JF1. Attach the NIC1
LED cable to display network activity.
Refer to the table on the right for pin
defi nitions.
NIC2 LED
The NIC2 (Network Interface Control-
ler) LED connection is located on pins
9 and 10 of JF1. Attach the NIC2
LED cable to display network activity.
Refer to the table on the right for pin
defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
7
Vcc
8
Control
NIC1 LED
Pin Defi nitions (JF1)
Pin# Defi nition
11
Vcc
12
NIC1 Active
NIC2 LED
Pin Defi nitions (JF1)
Pin# Defi nition
9
Vcc
10
NIC2 Active
HDD LED
The HDD (IDE Hard Disk Drive) LED
connection is located on pins 13 and
14 of JF1. Attach the IDE hard drive
LED cable to display disk activity.
Refer to the table on the right for pin
defi nitions.
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition
13
Vcc
14
HD Active
Power Fail LED
The Power Fail LED connection is lo-
cated on pins 5 and 6 of JF1. See the
table on the right for pin defi nitions.
Power Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
5
Vcc
6
Control
Note:
This feature is only available when using
redundant power supplies.
Summary of Contents for H8DSL-HTi
Page 1: ...H8DSL HTi USER S MANUAL Revision 1 0 ...
Page 8: ...1 2 H8DSL HTi User s Manual Notes ...
Page 9: ...Chapter 1 Introduction 1 3 Figure 1 1 H8DSL HTi Image ...
Page 20: ...1 14 H8DSL HTi User s Manual Notes ...
Page 46: ...2 26 H8DSL HTi User s Manual Figure 2 6 Driver Installation Display Screen ...
Page 68: ...4 18 H8DSL HTi User s Manual Notes ...