Superior VTDGT24NR Installation And Operation Instructions Manual Download Page 5

www.SuperiorFireplaces.US.com

127038-01A

5

Carefully follow the instructions below. This will ensure safe 

installation into a masonry, UL127-listed manufactured fire

-

place or listed outdoor firebox.

 

Minimum Clearances For Side Combustible Material, 

 

Side Wall and Ceiling 

A. Clearances from the side of the fireplace cabinet to any 

combustible material and wall should follow diagram in 

Figure 2.

 

Example:

 The face of a mantel, bookshelf, etc. is made 

of combustible material and protrudes 3½" from the wall. 

This combustible material must be 4" from the side of the 

fireplace cabinet (see Figure 2).

 

Note: When installing your gas logs into a manufactured 

firebox, follow firebox manufacturer’s instructions for mini

-

mum clearances to combustible materials.

B. Clearances from the top of the fireplace opening to the ceil

-

ing should not be less than 42".

INSTALLATION

Continued

Figure 2 - Minimum Clearance for Combustible to Wall 

*Minimum 16" from Side Wall 

*

Example

If Using Mantel

You must have noncombustible material(s) above the fireplace 

opening. Noncombustible materials (such as slate, marble, 

tile, etc.) must be at least 1/2" thick. With sheet metal, you 

must have noncombustible material behind it. Noncombus-

tible material must extend at least 8" up (for all models). If 

noncombustible material is less than 12", you must install the 

fireplace hood accessory. Even if noncombustible material is 

more than 12", you may need the hood accessory to deflect 

heat away from your mantel shelf. See Figure 3 and Figures 

4 and 5, page 6, for minimum clearances. 

IMPORTANT:

 If you cannot meet these minimum clearances, 

you must operate appliance with chimney flue damper open. 

Go to 

Installing Damper Clamp Accessory for Vented Opera-

tion

, page 7.

Heat Resistant
Material 

(A)

Figure 3 - Heat Resistant Material (Slate, Marble, Tile, 

etc.) Above Fireplace

Noncombustible 

Material Distance 

(A)

Requirements for Safe Installation

12" or more

Noncombustible material OK.

Between 8" and 12"

Install fireplace hood accessory 

(GA6050 or GA6053 see 

Accessories

page 23).

Less than 8"

Noncombustible material must be ex-

tended to at least 8". See 

Between 8" 

and 12"

, above. If you cannot extend 

material, you must operate appliance 

with flue damper open.

MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE 

MATERIALS

 

Side Wall 16", Ceiling 42"

Floor 5", Front: 36"

LOG SIZING REQUIREMENTS*

Log

Size

Minimum Firebox Size

Height

Depth

Front

Width

Rear

Width

LMF36-SC

29"

15.5"

32.5"

22.75"

LMF42-SC

29"

15.5"

39"

26.75"

LMF48-SC

29''

20''

47''

33''

GT24

29''

15.5''

32.5''

22.75''

GT30

29''

15.5''

39''

26.75''

GT36

29''

20''

47''

33''

Minimum Noncombustible Material Clearances
If Not Using Mantel

Note: If using a mantel proceed to If Using Mantel. If not using 

a mantel, follow these instructions

You must have noncombustible material(s) above the fireplace 

opening. Noncombustible materials (such as slate, marble, tile, 

etc.) must be at least 1/2" thick. With sheet metal, you must 

have noncombustible material behind it. Noncombustible 

material must extend at least 8" up (for all models). If noncom-

bustible material is less than 12", you must install the fireplace 

hood accessory. See Figure 3 for minimum clearances.

* When optional MFEB (MAGNIFLAME EMBER BURNER KIT) is 

used  with  these  burner  systems,  the  minimum  firebox  sizes  are 

different.  See MFEB instructions for minimum firebox sizes if this 

accessory is used.

Summary of Contents for VTDGT24NR

Page 1: ...er appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can caus...

Page 2: ...information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only in a solid fuel burning masonry or UL127 factory built fireplace or in a l...

Page 3: ...alls and furniture 9 Do not use this appliance as a wood burning appliance Use only the logs provided with the appliance Do not burn solid fuels in this appliance 10 Do not run appliance where flammab...

Page 4: ...these instructions ELECTRONIC IGNITION SYSTEM This appliance has an electronic ignitor to light appliance fuel supply INSTALLATION WARNING Aqualified service person must install appliance Follow all...

Page 5: ...If you cannot meet these minimum clearances you must operate appliance with chimney flue damper open Go to Installing Damper Clamp Accessory for Vented Opera tion page 7 Heat Resistant Material A Figu...

Page 6: ...el Clearances When Using Hood Minimum Non Combustible Material Minimum Non Combustible Material Height Distances to Underside of Mantel Top of Fireplace Opening Underside of Mantel Shelf 12 A 18 20 22...

Page 7: ...This will insure adequate air flow and guard against sooting and controls being dam aged Raisefireplacefloorwithnoncombustible material Make sure material is secure Installation Items Needed hardware...

Page 8: ...reads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged appliance valves WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas...

Page 9: ...um inlet gas supply pressure for purpose of input adjustment Figure 12 Gas Connection Pipe Cap Tee Nipple Joint Gas Control 3 Minimum Sediment Trap Equipment Shutoff Valve With 1 8 NPT Tap Approved Fl...

Page 10: ...ee Checking Gas Connections page 9 9 If logs were removed from appliance for install remote ac cessory replace logs see Installing Logs and Lava Rock Page 11 10 Place remote receiver on fireplace floo...

Page 11: ...anual Flamescontacting logs will create soot LOG PLACEMENT It is very important to install these logs exactly as instructed Do not modify logs Only use logs supplied with appliance Note Each log inclu...

Page 12: ...ertical portion of the burner tube Place this log on the base assembly by inserting it from the left side as shown in Figure 19 You will need to twist the log slightly to get it to fit against the bur...

Page 13: ...36 inch models D 028 See Figures 22 and 22A The split side of the log faces forward The log has a notch that fits around the burner tube on the right side The left side of the burner tube fits into th...

Page 14: ...ehind the knot on the top of the front right log 8 Find the back top log VFGT24 inch models D 062 or VFGT30 inch models D 023 or VTGF36 inch models D 029 See Figures 25 and 25A The left end of this lo...

Page 15: ...you don t smell gas go on the next step 6 Press in and turn control knob counterclockwise to the PILOT position Press in control knob for five 5 seconds see Figure 26 7 With control knob pressed in p...

Page 16: ...l areas burnersandcirculatingairpassagewaysofap plianceclean Inspecttheseareasofappliance before each use Have appliance inspected yearly by a qualified service person WARNING Failure to keep the prim...

Page 17: ...vary from pilot shown Thermocouple Thermopile 1 8 Pilot Burner Piezo Ignitor 3 8 to 1 2 LOGS If you remove logs for cleaning refer to Installing Logs and Lava Rock page 11 to properly replace logs Re...

Page 18: ...Gas Pressure in of water Max 14 W C Min 11 W C For purpose of input adjustment VTDGT24NR VTDGT30NR AND VTDGT36NR Rating Variable 29 000 40 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pre...

Page 19: ...n installed 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not cor rect REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing...

Page 20: ...lights keep control knob pressed in 30 seconds 3 Wait one minute for safety in terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or pro...

Page 21: ...from line Have gas line checked by local natural or pro pane LP gas company 3 Observe minimum installation clearances see pages 9 through 11 4 Clean burner see Cleaning and Maintenance page 16 or rep...

Page 22: ...ply propane LP only 3 Gas leak See Warning state ment at top of page 1 Low line pressure 2 ODS pilot is partially clogged 1 Gas leak See Warning state ment at top of page 2 Control valve or gas contro...

Page 23: ...wall above fireplace Fits openings 28 to 48 wide RECEIVER AND HAND HELD REMOTE CONTROL KIT MRC REMOTE READY MODELS ONLY For all models Allows the fireplace to be turned on and off by using a hand hel...

Page 24: ...SuperiorFireplaces US com 127038 01A 24 PARTS REMOTE READY CONTROL MODELS VTDGT24NR VTDGT24PR VTDGT30NR VTDGT30PR VTDGT36NR VTDGT36PR 1 2 5 6 8 9 10 13 14 15 16 17 18 19 20 21 23 24 25 22 11 12 12 7...

Page 25: ...ase 2 13 125603 01 Grate Stainlees MF42 1 125603 02 Grate Stainlees MF48 1 14 111435 01 Ignitor Electric 1 15 125019 01 Bracket Ignitor 1 16 116559 02 Shutter Air NG 1 116559 03 Shutter Air LP 1 17 09...

Page 26: ...NO PART NO LOG ID NO DESCRIPTION QTY 1 125948 01 D 061 125573 01 D 019 125591 01 D 027 Log Front Right 1 2 125948 02 D 060 125573 02 D 018 125591 02 D 026 Log Back Left 1 3 125948 03 D 059 125573 03...

Page 27: ...ing purchase date Usually we will ask you to return the part to the factory SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition appliance will not pro...

Page 28: ...ll produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product...

Page 29: ...eriorFireplaces US com 127038 01A 29 KEEP THIS WARRANTY Model located on product or identification tag Serial No located on product or identification tag Date Purchased Keep receipt for warranty verif...

Page 30: ...www SuperiorFireplaces US com 127038 01A 30 NOTES...

Page 31: ...www SuperiorFireplaces US com 127038 01A 31 NOTES...

Page 32: ...127038 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P127038 01...

Reviews: