background image

8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SUPERIOR

®

 B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 •  CARE AND OPERATION INSTRUCTIONS

OPERATION AND CARE OF YOUR APPLIANCE

       WARNING 

Young children should be carefully supervised when they are in the 

same room as the appliance.  Toddlers, young children and others 

may be susceptible to accidental contact burns.  A physical barrier is 

recommended if there are at risk individuals in the house.  To restrict 

access to a fireplace or stove, install an adjustable safety gate to keep 

toddlers, young children and other at risk individuals out of the room 

and away from hot surfaces.

       AVERTISSEMENT 

Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trou-

vent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants 

ou les adultes peuvent subir des brûlures s’ils viennent en contact avec 

la surface chaude.  Il est recommandé d’installer une barrière physique 

si des personnes à risques habitent la maison.  Pour empêcher l’accès 

à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure 

empêchera les tout petits, les jeunes enfants et toute autre personne à 

risque d’avoir accès à la pièce et aux surfaces chaudes.

Figure 1

GAS CONTROLS / CONTROL 

COMPARTMENT ACCESS

Fireplace gas controls are located in the lower 

control compartment under the firebox (see 

Figure 1

). Remove the control compartment 

door to access the controls.

Remove the control compartment door 

To access the valve open the lower control com-

partment door by pulling on the right and left 

top corners of the door. The door is hinged at 

the bottom. Remove the control compartment 

door by sliding it to the left and  then the right 

until it disengages from the fireplace corner 

post holes (

Figure 2

).

Reinstall the control compartment door 
If  necessary,  reinstall  the  door  by  inserting 

the tabs on each side of the door into the cor-

responding holes in the control compartment 

opening, one side first then the other. Swing 

the door gently up and fasten it by pushing it 

in until the magnetic latches catch and lock it 

in place (

Figure 2

).

Gas Flex Line

(

Gas Shut-Off Valve

 is behind 

door latch; see DETAIL, below)

Gas Control 

Valve

Piezo

(Millivolt 

units only) 

Spring 

Door Latch

(one of two) 

Lower Control 

Compartment 

(shaded area) 

CPI/IPI

Switch

(Electronic 

ValveOnly)

~

{

Note: Millivolt system shown. Electronic system controls are similarly located.

DETAIL: 

Gas Shut-Off Valve 

in ON position (gas line OPEN)

To shut OFF gas:

 Turn valve handle 

perpendicular (cross-wise) to gas line.

Figure 2 

Control Compartment Door Tab

Control 

Compartment 

Door Tab

Summary of Contents for SLBV 35

Page 1: ...r other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phon...

Page 2: ...ting Flame Height 9 Controls for Optional Outside Combustion Air Kit 9 Maintenance Instructions 10 Removing and Installing the Glass Enclosure Panel 11 Installing Volcanic Stone Glowing Embers Rockwoo...

Page 3: ...ction Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el con...

Page 4: ...t subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou u...

Page 5: ...a encendi ndola y apag ndola Limpie bien la placa del interruptor de pared para quitar el polvo y aceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Figura...

Page 6: ...l in these appliances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used These appl...

Page 7: ...ble 4 For elevations above 4500 feet contact your gas supplier or a qualified service technician Deration At higher elevations the amount of BTU fuel value delivered must be reduced by either using ga...

Page 8: ...gure 1 Gas Controls Control Compartment Access Fireplace gas controls are located in the lower control compartment under the firebox see Figure 1 Remove the control compartment door to access the cont...

Page 9: ...Valve Hi Lo Flame Control Knob Yellow Ground Wire from DFC Wire Harness Appliance Controls Operation of millivolt and electronic gas control systems differs Before lighting and operating your applianc...

Page 10: ...fied service techni cian inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged Homeowner must contact a qualifi...

Page 11: ...e only when the glass enclosure panel is installed Do NOT remove the glass enclosure panel un less necessary e g to gain access to compo nents within the firebox or to clean the glass Removing the Gla...

Page 12: ...de CO a colorless odorless toxic gas Separate the Embers rockwool into pieces about the size of a quarter Figure 8 Keep the pieces fluffed up not matted Distribute these pieces over the surface of the...

Page 13: ...s and the right front log over the right front brackets 2 1 Step 3 1 Right Front Log Nub 2 Position on the left rear log brackets 3 Step 4 Align the hole at the bottom of log 4 over the nub of log 2 a...

Page 14: ...ogs should be placed in the order shown Position the rear log on the brackets at the rear of the firebox with the log s notches directly over the brackets Proper log and twig placement is critical to...

Page 15: ...warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present f...

Page 16: ...BLY 3 8 Min 9 mm Igniter Rod Pilot Hood Proper Pilot Flame Appearance Figure 14 1 Locateadjustmentrodandadjustairshutter to the standard setting as shown in Figure 13 adjustment rod is located in the...

Page 17: ...ation If during appliance operation the flame goes out independently of the burner ON OFF switch the safety limit switch may have tripped Some causes for a tripped safety limit switch include the foll...

Page 18: ...______________________________ Serial Number_________________________________________________________ Date Installed__________________________________________________________ Gas Type Used____________...

Page 19: ...POWER ADAPTOR HOT NEUTRAL OPTIONAL GROUND BATTERY HOLDER DFC WIRE HARNESS SPARK WIRE CABLE PILOT GROUND WIRE PILOT SENSOR CABLE HOOD IGNITER ROD FLAME SENSOR PILOT TUBE OPTIONAL CPI SWITCH OFF O INTER...

Page 20: ...temp in F or C Flame icon and low battery indicator Includes batteries Wall clip included Receiver may be wall mounted or placed in the control compartment Includes white face plate Flame icon Low ba...

Page 21: ...aces Touch Up Paint Kit all models Cat No ModelNo Description 90L73 FTPK B Touch Up Paint Black PA I N T Firebox Liner Kits Cat No ModelNo Description H8083 BLPKB 35TB 35 Buff Traditional H8085 BLPKB...

Page 22: ...eps 5 through 9 If knob does not pop up when released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay li...

Page 23: ...le bouton et il sortira subitement La veilleuse devrait rester allum e Si elle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et a...

Page 24: ...ire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and...

Page 25: ...oir une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du r cepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouton ON OF...

Page 26: ...m being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate appliance checko...

Page 27: ...witchisusedforburner operation if the standard burner OFF ONswitchisstillinstalledon applianceitmustbeinthe OFF position Optional remote switch kits wall switch timer or remote control A Wallswitchorw...

Page 28: ...s call a service technician if required C Pilot flame is not engulfing the sensor Call a service technician D Obstructed vent system Call a service technician 4 Soot is present on the glass and panels...

Page 29: ...H7718 1 7 Orifice Main Burner Natural Gas H1236 1 99K75 1 Orifice Main Burner Propane Gas 62L37 1 19L52 1 8 Bag of Glowing Embers Rockwool 88L53 1 88L53 1 Bag of Decorative Volcanic Stone 80L42 1 80L...

Page 30: ...eplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNOX and other related LENNOXmarksareregisteredorcommonlawtrademarksofLennoxIndustriesInc andareused with permission Pr...

Reviews: