 B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 •  CARE AND OPERATION INSTRUCTIONS

Safety and  

Your Fireplace

 To prevent severe burns and injuries, install 

a screen or physical barrier to prevent direct 

contact with the glass.

To order a FREE Lennox

®

 

SAFETY GUARD 

 

for your fireplace, see details at left.

 Follow the safety instructions below 

and be sure everyone in your household 

understands this burn hazard:

• 

The surfaces on your fireplace get  

EXTREMELY HOT! 

• 

The glass on the front 

of the fireplace reaches 

EXTREMELY HIGH 

temperatures and can 

cause severe burns if touched.

• 

Keep children away from an operating 

fireplace. Closely supervise children in 

any room where a fireplace is operating 

to prevent contact with glass.

• 

Keep clothing, furniture, 

gasoline, and other 

flammable liquids away 

from the fireplace.

• 

Even after the gas is turned off, fireplace 

surfaces remain extremely hot.

 Be sure to attach the enclosed 

Safety-in-

Operation Warnings

 where you turn on your 

fireplace, to help remind everyone of the 

dangers associated with high temperatures 

(see 

Page 5

).

 Read 

Important Safety Information

 on 

Page 4

.

All parts of your Lennox 

Hearth Products fireplace  

get EXTREMELY HOT! 

TABLE OF CONTENTS

Safety and Your Fireplace

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

2

Important Safety Information

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

4

Attaching the Safety-in-Operation Warnings

  . . . . . . . . . . . . . . . . . . . . . . . . .  

5

Appliance Installation, Service, and Maintenance Notices

  . . . . . . . . . . . . . . . . . 6

Appliance Operation Notices   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

General Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6

   Operation/Care of Your Appliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Gas Controls / Control Compartment Access  . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

   Appliance Controls  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

   Lighting the Appliance   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

   ON/OFF Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

   Adjusting Flame Height  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Controls for Optional Outside Combustion Air Kit  . . . . . . . . . . . . . . . . . . . . . . . 9

Maintenance Instructions

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Removing and Installing the Glass Enclosure Panel . . . . . . . . . . . . . . . . . . . . . 11

Installing Volcanic Stone, Glowing Embers (Rockwool), and Logs

  . . . . . . . . . 12

   SLBV-35 Log Placement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

   SLBV-40 Log Placement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Burner Air Shutter Adjustments: 

   Flame Appearance and Sooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

   Air Shutter Adjustment Guidelines   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

   Burner Air Shutter Adjustment Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Appliance Checkout:

   Millivolt Appliance Checkout

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

   Electronic Appliance Checkout

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Spillage Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

   Manually-Reset Safety Limit Switch

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Ordering Replacement Parts   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Product Reference Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Wiring Diagrams

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Accessory Components  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Lighting Instructions  -  Millivolt

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Lighting Instructions  -  Electronic  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Maintenance Schedule

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Troubleshooting Guide  -  Millivolt

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Troubleshooting Guide  -  Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Replacement Parts List   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Thank you for your purchase. We appreciate your business!

Please carefully read and follow all instructions in this manual. 

 

Pay special attention to all warnings and safety information.

Following these safety, care, and operation instructions will help ensure 

many years of dependable and enjoyable service from your fireplace.

Register your product online today! 

To  help  us  keep  you  up-to-date  on  product  information  and  offers, 

please  take  a  few  moments  to  register  your  product  online  at:

 

www.lennoxhearthproducts.com (Owner Resources > Product Registration)

 

FREE

 

SAFETY

 

GUARD

 

OFFER

 

The Lennox

®

 

SAFETY GUARD

 protects against severe burns and injuries 

by preventing direct contact with the front glass surface of your fireplace.

To receive your 

FREE SAFETY GUARD, call 1-800-655-2008

 

or visit www.

lennoxhearthproducts.com

 (Owner Resources > Safety First).

Note: 

Safety Guards may not be available for some older models no longer in production.

 

Summary of Contents for SLBV 35

Page 1: ...r other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phon...

Page 2: ...ting Flame Height 9 Controls for Optional Outside Combustion Air Kit 9 Maintenance Instructions 10 Removing and Installing the Glass Enclosure Panel 11 Installing Volcanic Stone Glowing Embers Rockwoo...

Page 3: ...ction Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el con...

Page 4: ...t subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou u...

Page 5: ...a encendi ndola y apag ndola Limpie bien la placa del interruptor de pared para quitar el polvo y aceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Figura...

Page 6: ...l in these appliances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used These appl...

Page 7: ...ble 4 For elevations above 4500 feet contact your gas supplier or a qualified service technician Deration At higher elevations the amount of BTU fuel value delivered must be reduced by either using ga...

Page 8: ...gure 1 Gas Controls Control Compartment Access Fireplace gas controls are located in the lower control compartment under the firebox see Figure 1 Remove the control compartment door to access the cont...

Page 9: ...Valve Hi Lo Flame Control Knob Yellow Ground Wire from DFC Wire Harness Appliance Controls Operation of millivolt and electronic gas control systems differs Before lighting and operating your applianc...

Page 10: ...fied service techni cian inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged Homeowner must contact a qualifi...

Page 11: ...e only when the glass enclosure panel is installed Do NOT remove the glass enclosure panel un less necessary e g to gain access to compo nents within the firebox or to clean the glass Removing the Gla...

Page 12: ...de CO a colorless odorless toxic gas Separate the Embers rockwool into pieces about the size of a quarter Figure 8 Keep the pieces fluffed up not matted Distribute these pieces over the surface of the...

Page 13: ...s and the right front log over the right front brackets 2 1 Step 3 1 Right Front Log Nub 2 Position on the left rear log brackets 3 Step 4 Align the hole at the bottom of log 4 over the nub of log 2 a...

Page 14: ...ogs should be placed in the order shown Position the rear log on the brackets at the rear of the firebox with the log s notches directly over the brackets Proper log and twig placement is critical to...

Page 15: ...warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present f...

Page 16: ...BLY 3 8 Min 9 mm Igniter Rod Pilot Hood Proper Pilot Flame Appearance Figure 14 1 Locateadjustmentrodandadjustairshutter to the standard setting as shown in Figure 13 adjustment rod is located in the...

Page 17: ...ation If during appliance operation the flame goes out independently of the burner ON OFF switch the safety limit switch may have tripped Some causes for a tripped safety limit switch include the foll...

Page 18: ...______________________________ Serial Number_________________________________________________________ Date Installed__________________________________________________________ Gas Type Used____________...

Page 19: ...POWER ADAPTOR HOT NEUTRAL OPTIONAL GROUND BATTERY HOLDER DFC WIRE HARNESS SPARK WIRE CABLE PILOT GROUND WIRE PILOT SENSOR CABLE HOOD IGNITER ROD FLAME SENSOR PILOT TUBE OPTIONAL CPI SWITCH OFF O INTER...

Page 20: ...temp in F or C Flame icon and low battery indicator Includes batteries Wall clip included Receiver may be wall mounted or placed in the control compartment Includes white face plate Flame icon Low ba...

Page 21: ...aces Touch Up Paint Kit all models Cat No ModelNo Description 90L73 FTPK B Touch Up Paint Black PA I N T Firebox Liner Kits Cat No ModelNo Description H8083 BLPKB 35TB 35 Buff Traditional H8085 BLPKB...

Page 22: ...eps 5 through 9 If knob does not pop up when released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay li...

Page 23: ...le bouton et il sortira subitement La veilleuse devrait rester allum e Si elle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et a...

Page 24: ...ire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and...

Page 25: ...oir une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du r cepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouton ON OF...

Page 26: ...m being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate appliance checko...

Page 27: ...witchisusedforburner operation if the standard burner OFF ONswitchisstillinstalledon applianceitmustbeinthe OFF position Optional remote switch kits wall switch timer or remote control A Wallswitchorw...

Page 28: ...s call a service technician if required C Pilot flame is not engulfing the sensor Call a service technician D Obstructed vent system Call a service technician 4 Soot is present on the glass and panels...

Page 29: ...H7718 1 7 Orifice Main Burner Natural Gas H1236 1 99K75 1 Orifice Main Burner Propane Gas 62L37 1 19L52 1 8 Bag of Glowing Embers Rockwool 88L53 1 88L53 1 Bag of Decorative Volcanic Stone 80L42 1 80L...