H07023380 / DT2000477-03
1.8 MINIMUM SAFETY DISTANCES
DT2011553-02
9
English
- The fl ueway must be made by specialised personnel or fi rms, as outlined below.
- The fl ue must be installed in such a way as to guarantee that periodic
cleaning can be carried out without dismantling any parts whatsoever.
- Pipes should
always
be sealed with silicone (not cement-based sealants) or
specially adapted gaskets/seals, which retain their strength and elasticity at
high temperatures (250°C), and should be fi xed with 3.9 mm ø self-tapping
screws.
1.9 CONNECTION TO THE FLUE
DT2010229-04
The pellet stove is not the same as other stoves. It has a forced
draught of fl ue gas by a fan, which keeps the fi rebox in a vacuum
and the entire fl ueway slightly pressurised. For this reason the
fl ue must be completely airtight and correctly installed to ensure
both trouble-free operation and user safety.
Do not install dampers or valves that could block the passage of
fl ue gas.
Do not connect to a fl ueway into which other appliances (boilers,
extractor hoods, etc.) discharge fumes or vapours.
Using the relative pipe clips, fi x the fl ue to the wall so that it does not
weigh on the smoke fan.
Fig. 19
DT2030337-00
Keep any combustible product such as wooden furniture,
curtains, carpets, combustible liquids, etc. well away from the
stove when it is lit (minimum distance 80 cm).
It is recommended that greater distances than those indicated
above be left all round the stove to make any necessary work
on the appliance easier.
Parete posteriore
Pa
re
te
la
te
ra
le
Pa
re
te
la
te
ra
le
B
B
A
D
STUFA
E
E
F*
F*
SCARICO POSTERIORE
SC
A
R
IC
O
LA
T
E
RA
LE
del focolare
Zona radiante dell'apertura
C
Protezione pavimento
DT2032441-0
Install the product in compliance with the recommended safety distances
from heat sensitive or inflammable materials and not inflammable, from
load bearing and other walls and also from wooden elements, furniture, etc.
In the case of flooring that is heat sensitive or inflammable the floor must
be protected with non-combustible insulating material, e.g. sheets of steel
plate, marble, tiles, etc.
The minimum distances are:
Connection to the flue must respect minimum safety distances from heat-
sensitive structural components or inflammable materials (wood panelling,
beams or ceilings, etc) shown in the figures.
* = Values referred to the use of original Superior flue pipes; if other pipes
are used, the safety fire regulations or fire codes of reference are applicable.
A 10 cm from the wall behind the stove
B 20 cm from the side wall
C 80 cm in the heat radiation area and from the hot air fan outlet
D 50 cm fl oor protection
E 30 cm (measured from the inner edge of the door)
F 5 cm from the fl ue gas outlet on the rear wall
DT2030335-00
Fig. 16
Fig. 17
Fig. 18
DT2032226-00
STOVE
Rear wall
Side wall
Side wall
Radiating Zone
Floor protection
Rear fl ue gas outlet
Side fl
ue gas
outlet
Tee with sealing plug
Straight reducer
Ø 80/100 mm
Ø 100 mm
Ø 80 mm