H07023380 / DT2000477-03
The appliance is designed for connection to an external room thermostat.
To connect the external thermostat use cable type 2x0.5mm
2
clamped with
a PG7 cable gland to be inserted in the appropriate hole in the rear panel
(Fig. 32).
This operation must be carried out by authorised personnel.
Fig. 30
To install, proceed as follows:
- Cut off the electricity to the appliance;
- Remove the right side panel (see the paragraph
REMOVING THE
CLADDING
);
- Remove the knockout to be found in the rear panel (position 4 – Fig. 28);
- Clamp the thermostat cable with the PG7 cable gland and insert the gland
into the hole in the rear panel (Fig. 32);
- Connect the thermostat terminal to the two-pin terminal of the electronic
board (Fig. 31);
- Refi t the panel, proceeding in the reverse order to removal.
1 Thermostat.
2 Electronic board 2-pin terminal.
3 Cable gland.
4 Thermostat cable terminal.
4.2 INSTALLING THE EXTERNAL THERMOSTAT
DT2011598-00
English
Installation can be carried out with any type of room thermostat
but requires a PG7 cable gland similar to the one shown in fi g
30. To connect the thermostat to the electronic board, see the
wiring diagram.
DT2032283-0
Fig. 31
DT2032284-0
Fig. 32
4.3 REMOVING THE CLADDING
DT2011600-00
DT2032298-0
A
B
Fig. 33
If work has to be carried out inside the cladding, the side panels must be
removed as follows:
- remove the upper grille [A] after unscrewing the 4 fastening screws [B].
(Fig. 33)
- Remove the 2 screws [C] that secure the lower front panel [D], lift it
slightly and then pull it outwards to remove. (Fig. 34)
DT2032299-0
D
C
Fig. 34
16
DT2030076-00
Summary of Contents for MONIA
Page 42: ...H07023380 DT2000477 03 42 ...