Superior BRT4036TEN Installation And Operation Instructions Manual Download Page 31

SuperiorFireplaces.US.com

126737-01_E

31

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900223-00, Rev. A  10/2015

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior

®

 Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior

®

 Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body and fi rebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against 

thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited 

Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement 

is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevail-

ing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to fi ve years. THERE ARE EXCLUSIONS AND LIMITATIONS 

to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and fi rebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fi replace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting confi gurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a 

particular use or purpose, and there is no implied condition of fi tness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefi ts and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without fi rst obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Summary of Contents for BRT4036TEN

Page 1: ...RMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO WARNING FIRE OR EXPLOSION HAZ...

Page 2: ...in the Common wealth of Massachusetts NOTICE Young children should be carefully supervised when they are in the same room as the appliance Tod dlers young children and others may be susceptible to acc...

Page 3: ...er flammable objects are less than 36 from front and 42 from top of fireplace For side clearances see Figure 6 page 6 in high traffic areas in windy or drafty areas 5 This fireplace reaches high tempe...

Page 4: ...liances You will also need a building permit from your local Building and Safety Commissioner before installing this appliance other wise your insurance co may not cover this appliance CAUTION Donotco...

Page 5: ...Manifold Pressure 10 WC 2 50 kPa 10 WC 2 50 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13 WC 3 23 kPa Orifice Size 52 50 Model 36 Model 42 Model 3...

Page 6: ...terial May Be Used TOP VIEW SAFE ZONE Perpendicular Wall Figure 6 Side Clearances Top View Cross Section CLEARANCES Minimum clearances to combustibles are Back and Sides of Outer Surround 0 min Drywal...

Page 7: ...5 16 above bottom of appliance The gas line must be installed through lower left side access point or alternate access hole in the bottom of appliance see Figure 17 page 11 4 Repack insulation around...

Page 8: ...tallation Standing codes requirements concerning B type vent installations may vary within your state province or local codes jurisdiction There fore it is recommended that you check with your local b...

Page 9: ...Roof Pitch H Min Feet Meter Flat to 6 12 1 0 0 30 6 12 to 7 12 1 25 0 38 Over 7 12 to 8 12 1 5 0 46 Over 8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 1...

Page 10: ...eady to use 5 Replace front refractory access panel Figure 16 Manual Shutoff Valve Installation Typical Exterior Wall Gas Shutoff Installation Key Extension Shutoff Valve Figure 15 Installing Battery...

Page 11: ...leak is detected Complete your gas installation by connecting incoming gas line with flexible gas line Secure tightly with wrench but DO NOT OVER TIGHTEN Figure 19 Connecting Flexible Gas Line to Mill...

Page 12: ...tch on log 2 resting front end on top of log 1 see Figure 24 4 Place upper end of log 4 into notch on log 2 as shown in Figure 24 Rest lower end of log 4 onto middle grate finger as shown in Figure 25...

Page 13: ...ure 29 5 Place upper end of log 5 into notch on top inner right of log 1 see Figure 29 Rest lower end of log 5 on middle grate finger as shown in Figure 30 6 Place log 6 into notch on top right of log...

Page 14: ...al bottom of appliance see Figure 32 INSTALLATION Continued INSTALLING OPTIONAL GLASS DOOR ACCESSORY CAUTION Use only glass doors certified for use with this appliance Note Glass door may be heavy for...

Page 15: ...doors partially open can result in improper venting of flue products WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors...

Page 16: ...control system and any gas control which has been under water LIGHTING INSTRUCTIONS NOTICE Duringinitialoperationofnewfireplace burn ing logs will give off a paper burning smell Orange flame will als...

Page 17: ...Off Gas to Appliance page 16 see Troubleshooting page 20 CLEANING AND MAINTENANCE WARNING Installation and repair should be done by a qualified service person The appliance should be inspected before...

Page 18: ...EV1 MV P MV HIGH VOLTAGE PV GND TH TR BLACK BLACK BLACK GAS VALVE MICRO SWITCH IF EQUIPPED LIMIT SWITCH IF EQUIPPED NO NC PILOT BURNER IGNITOR ORANGE RED RED BLUE WHITE BLACK TRANSFORMER GROUND 24 VAC...

Page 19: ...sit our web site at Superiorfireplaces US com REPLACEMENT PARTS See Pages 22 to 25 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be orde...

Page 20: ...nt volt age REMEDY 1 Check to see if you have gas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after re peated attempts...

Page 21: ...2 For propane LP gas low fuel supply 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve an...

Page 22: ...29 26 36 NG LP MODEL CAT NO BRT4036TEN F0816 BRT4036TEP F0817 BRT4336TEN F0820 BRT4336TEP F0821 BRT4536TEN F0824 BRT4536TEP F0825 BRT4042TEN F0828 BRT4042TEP F0829 BRT4342TEN F0832 BRT4342TEP F0833 B...

Page 23: ...1 J4055 GRATE ASSEMBLY 1 27 J4048 PAN BURNER 1 J4049 PAN BURNER 1 28 J4053 TUBE BURNER 1 J4083 TUBE BURNER 1 29 J4051 BRACKET BURNER 1 30 J4094 SHIELD PILOT 1 J4095 SHIELD PILOT 1 31 J7320 CLIP BURNE...

Page 24: ...D STK 1 J7617 REFRACTORY 36 LT RED HER 1 13 J6370 REFRACTORY RT 36 RED STK 1 J7619 REFRACTORY 36 RT RED HER 1 14 J7515 REFRACTORY REAR 36 RED STK 1 J7630 REFRACTORY 36 REAR RED HER 1 15 J6373 REFRACTO...

Page 25: ...obtain any of these parts Never use substitute materials not approved by IHP Use of non approved parts can result in poor performance and safety hazards KEY NO CATALOG NO DESCRIPTION QTY J4096 LOG SET...

Page 26: ...s finish F0998 FD36P 36 Fixed Glass Door Platinum finish F0999 FD42 42 Fixed Glass Door Black finish F1000 FD42B 42 Fixed Glass Door Brushed Brass finish F1001 FD42P 42 Fixed Glass Door Platinum finis...

Page 27: ...4 PT36P 36 Perimeter Trim Kit Platinum F1045 PT42 42 Perimeter Trim Kit Black F1046 PT42B 42 Perimeter Trim Kit Brushed Brass F1047 PT42P 42 Perimeter Trim Kit Platinum PROPANE NATURAL GAS CONVERSION...

Page 28: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 29: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...urn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a f...

Page 32: ...ealer name P126737 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produ...

Reviews: