www.SuperiorFireplaces.US.com
126826-01A
16
INSTALLATION
Continued
INSTALLING LOGS
WARNING: Failure to posi-
tion the parts in accordance
with these diagrams or failure
to use only parts specifically
approved with this heater may
result in property damage or
personal injury.
Log Support Brackets
If installing a LBG36-SM, attach log support
brackets before installing logs. These brack-
ets are provided with the BG(E)2436 series
burner systems.
1. Install left bracket to left side of chassis us-
ing 2 screws provided (see Figure 17).
2. Install right bracket to right front of chassis
using 2 screws provided (see Figure 17).
Figure 17 - Installing Log Support Brackets
Left Log
Support
Bracket
Chassis
Right Log
Support
Bracket
Right Front of Chassis
Figure 14 - Equipment Shutoff Valve
Figure 15 - Checking Gas Joints
(Propane/LP Only)
Thermostat Gas
Valve or Control
Valve Location
Propane/LP
Supply Tank
Equipment
Shutoff Valve
Open
Closed
Equipment
Shutoff
Valve
Gas Meter
Figure 16 - Checking Gas Joints (Natural
Gas Only)
Thermostat Gas Valve or
Control Valve Location
Equipment Shutoff Valve
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Fig-
ure 14).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shutoff
valve to thermostat gas valve (see Figure
15 or 16). Apply noncorrosive leak detection
fluid to all joints. Bubbles forming show a
leak.
5. Correct all leaks at once.
6. Light heater (see
Operation
, page 26,
depending on your model). Check all other
internal joints for leaks.
7. Turn off heater (see
To Turn Off Gas to
Appliance
, page 27.
SWITCH LOG
Log sets LBG(18,24,30,36)-SM, and
LBG(18,24,30)-BM come with a switch log that
is not used with these burner systems. The switch
log can be used as a decorative log place on
the hearth. Do not place on the burner system.