THE WARRANTY

Innovative Hearth Products (“IHP”) 20 Year Limited Warranty warrants your Superior™ Brand wood stove or insert ("Product") to be free from defects in materials and 

workmanship at the time of manufacture. The Product body, firebox, removable air tubes and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 

20 Year Limited Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workman-

ship during the 20 Year Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered 

components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is 

applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to one year. THERE 

ARE EXCLUSIONS AND LIMITATIONS to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this 20 Year Limited Warranty. The following are warranted as follows:

Cast iron parts

 – Replacement for one year from the date of installation

Electrical components

 – Repair or replacement for one year from date of installation

Gaskets

 – Replacement for one year from the date of installation

Refractory & screens

 – Replacement for two years from date of installation. Excludes hairline cracks

Removable air tubes

 – Repair or replacement for five years from date of installation. IHP prevailing labor rates for one year from the date of installation.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component, unless otherwise noted Parts not otherwise listed carry a 90 day 

warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Opera-

tion Manual provided with the product. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood, coal or plywood and wood 

products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly; IHP stoves and inserts are 

approved for burning dry seasoned wood only.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with 

the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

Coverage of this 20 Year Limited Warranty is conditional upon the appliance being operated without the use of grates, irons or any other method to elevate the fire.

IHP is not responsible for inadequate system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions which 

may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by inadequate 

chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due 

to any malfunction or defect in equipment are not covered by this 20 Year Limited Warranty. All replacement or repair components will be shipped F.O.B. from the nearest 

stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street Russellville, AL 35654 or visit our website at WWW.IHP.US.COM.

10

/14

/20

15

Summary of Contents for WXS2016

Page 1: ...aire la demande Num ro de la pi ce 900917 01 This appliance must be properly installed and operated in order to prevent the pos sibility of a house fire Please read this entire installation and operat...

Page 2: ...ation 3 Testing Information 4 Draft Requirements 4 Selecting the Proper Venting System 4 Negative Pressure Warning 5 Clearances to Combustibles 6 7 Floor Protection 6 Chimney and Connector 6 Component...

Page 3: ...h your local building department for requirements in your area 13 Inspectyourchimneyatleastonceamonthduringtheburn ing season to check for soot and creosote accumulations Any accumulations over 1 8 th...

Page 4: ...cleaning Overfiring of a stove is a condition where excessive temperatures are reached beyond the design capabilities of the appliance The damage that occurs from overfiring is not covered under the m...

Page 5: ...d by many common household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Also the combu...

Page 6: ...ed for mobile homes but connector pipe may be double wall single wall or single wall with shield as listed above This appliance may be vented into a code approved masonry chimney with flue liner WARNI...

Page 7: ...19 1 2 9 5 8 8 6 15 37 5 8 46 3 4 34 7 8 16 0 84 57 1 2 305 232 495 245 200 152 381 956 1188 886 406 0 2134 1461 CANADA inches millimeters PIPE INSTALLATION A 3 B 1 C 3 D 1 E 8 F 1 G 3 H 2 I 6 J 2 K 7...

Page 8: ...ions only 1 4 Diagrams illustrations and photographs are not to scale consult installa tion instructions Product designs materials dimensions specifications colors and prices are subject to change or...

Page 9: ...all metal chimney at least 6 in diameter or to a masonry chimney with a flue passage of at least 48 square inches It is required that a chimney connector pipe not extend further than the inner wall of...

Page 10: ...______________________________________ ______________________________________________________ ______________________________________________________ ___________________________________________________...

Page 11: ...n shall be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from con nector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and...

Page 12: ...register must not be installed more than ten 10 feet 3050 mm above the base of the stove c The fresh air must come from outside the house The air intake must not draw air from the attic from the base...

Page 13: ...ll install the baffle blanket It will be installed with the 11 dimension from the front to rear of the firebox Install by lifting it into place between the front and rear baffle Place the blanket over...

Page 14: ...5 F 10 F 9 F 8 A 4 F 6 D 1 F 2 F 3 D 7 F 11F 12A 13F 14F 15G 16E Figure 15 Side Cut A Way View of Firebox Baffle Blanket Front Baffle Board Rear Baffle Board Firebox Brick Baffle Insulation Parts Figu...

Page 15: ...able from all IHP dealers Opening Door Lift handle and pull to open door Closing Door Hold handle lifted swing door closed then push handle down to engage latch Handle Door OPERATING HINTS 1 Burn only...

Page 16: ...ing appliance it is important to become familiar with how the damper control affects heat output and the overall temperature of the appliance A stove thermom eter can be a helpful tool to help ensure...

Page 17: ...chieve heat output rates that exceed heater design specifica tions can result in permanent damage to the heater Figure 22 Figure 23 OK 4 4 8 Standard Cord of Wood What does Well Seasoned mean When a t...

Page 18: ...need to have sufficient temperatures inside the firebox for thorough combustion The best method for determining if you have sufficient temperatures is to watch the brick lining in your firebox When yo...

Page 19: ...he stove is burned with the blower opening unobstructed Figure 24 The optional blower is controlled by a Dial a Temp see Figure 24 It contains an On Off line switch with variable speed control from lo...

Page 20: ...on ing are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Some people are more affected by carbon monoxide than others including pregnan...

Page 21: ...a chimney fire THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUC...

Page 22: ...ior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotcleanwithanymaterials which may scratch or otherwise damage the glass Scratches on...

Page 23: ...2 3 See Poor Draft section above and Cleaning Glass on Pages 4 and 22 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN 2 Check the...

Page 24: ...Draft Rod Knob 9 F4088 Ash Lip Kit includes hardware 1 4 5 11 6 3 12 13 14 15 16 16 16 16 17 16 21 19 20 16 17 16 19 16 16 17 18 16 22 7 10 9 8 2 Item Cat Description 10 F4101 Pedestal Assembly 11 H5...

Page 25: ...ND UZI UZI Outside Air Ducting Kit includes 4 insulated flex x 10 long AND F4062 OUTAIRKIT ES Outside Air Panel and Air Channel Kit includes rear pedestal panel and side and front air channels MISC H8...

Page 26: ...anufactured By INNOVATIVE HEARTH PRODUCTS 1502 14th St NW Auburn WA 98001 USA PREVENT HOUSE FIRES Installanduseonlyinaccordancewithmanufac turer sinstallationandoperatinginstructionsand your local bui...

Page 27: ...cessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves and inserts are approved for burning dry seasoned wood only c damages caused by failing to pr...

Page 28: ...give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date...