WARNING: Never install the appliance
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing or other
fl ammable objects are less than 36" from
front, 42" from top of appliance; for side
clearances see
Figure 4, Page 10
• in high traffi c areas
• in windy or drafty areas
CAUTION: This appliance creates warm
air currents. These currents move heat
to wall surfaces next to appliance. In-
stalling appliance next to vinyl or cloth
wall coverings or operating appliance
where impurities (such as, but not
limited to, tobacco smoke, aromatic
candles, cleaning fl uids, oil or kero-
sene lamps, etc.) in the air exist, may
discolor walls or cause odors.
WARNING: Maintain the minimum
clearances. If you can, provide greater
clearances from fl oor, ceiling and
adjoining wall.
MINIMUM FIREPLACE CLEARANCE TO
COMBUSTIBLE MATERIALS
Side Wall 16", Ceiling 42"
Floor 5", Front: 36"
WARNING: Before installing in a
solid fuel-burning fi replace, the chimney
fl ue and fi rebox must be cleaned of soot,
creosote, ashes and loose paint by a
qualifi ed chimney cleaner. Creosote will
ignite if highly heated. A dirty chimney
fl ue may create and distribute soot within
the house. Inspect chimney and fi rebox
fl ue for damage. If damaged, repair fl ue
and fi rebox before operating appliance.
INSTALLATION
Continued
IMPORTANT
:
Vent-free appliances add moisture to
the air. Although this is benefi cial, installing appli-
ance in rooms without enough ventilation air may
cause mildew to form from too much moisture.
See
Air for Combustion and Ventilation
,
Page 6
.
CHECK GAS TYPE
Use the correct type of gas (natural or propane/LP).
If your gas supply is not the correct gas type, do not
install appliance. Call dealer where you purchased
the appliance for proper type appliance.
INSTALLATION AND CLEARANCES FOR
VENT-FREE OPERATION
LOG SIZING REQUIREMENTS
Log
Size
Minimum Firebox Size
Height
Depth
Front
Width
Rear*
Width
18"
20"
14"
28"
20"
24"
20"
14"
32"
22"
30"
20"
14"
40"
30"
Carefully follow the instructions below. This will en-
sure safe installation into a masonry, UL127-listed
manufactured fi replace or listed vent-free fi rebox.
Minimum Clearances For Side Combustible
Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in
Figure 4, Page 10
.
Example:
The face of a mantel, bookshelf, etc.
is made of combustible material and protrudes
3-1/2" from the wall. This combustible material
must be 4" from the side of the fi replace cabinet
(see
Figure 4, Page 10
)
.
WARNING: Make sure the selector
switch is in the OFF position before
installing heater.
NOTICE: State or local codes may only
allow operation of this appliance in a
vented confi guration. Check your state
or local codes.
WARNING: This appliance is
equipped for either natural gas or
propane/LP gas but not both. Gas type
is indicated on the rating plate. Field
conversion is not permitted.