TF Series Burner System - Log Compatibility
Chart
Burner System
Models
Fiber Log
Models
Concrete Log
Models
TF18NV
TF18PV
LTF18MM
LTF18RS
LTF18WT
TF2430NV
TF2430PV
LTF24MM
LTF30MM
LTF24RS
LTF30RS
LTF24WT
LTF30WT
Figure 20 TF Series Burner System- Log
Compatibility Chart
LTF(18,24,30)-MM LOG PLACEMENT
It is very important to install the logs exactly as
instructed. Do not modify logs. Only use logs sup-
plied with appliance or as identifi ed for use with the
appliance as shown in
Figure 20
. Each log includes
reference numbers formed in the bottom or back
of the log. The circled number indicates the order
it is placed on the burner system. The remaining
numbers indicate the size burner system the logs
are designed to fi t. For example, the fi rst log for
a 24 inch burner system will include a circled 1
and also a 24.
1
Figure 21 - Installing Log # 1
''U'' -
Burner
Base
assembly
2. Place the middle log (#2) in front of the U-
burner and against the edges of the plate as
shown in
Figure 22, Page 18
.
3.
Place the front left log (#3) onto the base as-
sembly between the middle log (#2) and the
grate fi ngers. The back of the front left log (#3)
will rest against the front of the middle log (#2).
The notch at the end of the front left log (#3)
will fi t around the grate bar. See
Figure 23,
Page 18
.
4. Place the front right log (#4) onto the base
assembly between the middle log (#2) and the
grate. The back of the front right log (#4) will
rest against the front of the middle log (#2).
The notch in the end of the front right log (#4)
will fi t around the grate bar. See
Figure 24,
Page 18
.
The circled 1 indicates this is the fi rst log to be
installed. The 24 indicates this log belongs to
a 24 inch log set.
See
Pages39-41
for reference
numbers detail.
1. Place the rear log (#1) on base assembly as
shown in
Figure 21
. Log will fi t over right end
of burner and rest in middle of U-burner.
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only parts
specifi cally approved with this appli-
ance may result in property damage
or personal injury.
WARNING: After installation and
periodically thereafter, check to en-
sure that no fl ame comes in contact
with any log. With heater set to Hi,
check to see if fl ames contact any
log. If so, reposition logs according
to log installation instructions in this
manual. Flames contacting logs will
create soot.
INSTALLING LOGS, EMBERS AND