POSSIBLE CAUSE

1. Control knob not fully pressed in

2. Control knob not pressed in long 

enough

3. Safety interlock system has been 

triggered 

4. Equipment shutoff valve not fully 

open

5. Pilot flame not touching thermo

-

couple, which allows thermo-

couple to cool, causing pilot flame 

to go out. This problem could be 

caused by one or both of the fol-

lowing:

  A) Low gas pressure

  B) Dirty or partially clogged ODS/

pilot 

6. Thermocouple connection loose 

at control valve 

7. Thermocouple  damaged

8. Control valve damaged

1. Inlet gas pressure is too low

2. Burner orifice(s) clogged

3. Thermopile leads disconnected 

or improperly connected.

4. Remote selector in OFF position

5. Wire disconnected from gas con-

trol

1. Manifold pressure is too low

2. Burner orifice clogged

3. Mislocated crossover tube

1. Burner orifice is clogged or dam

-

aged

2. Damaged  burner

3. Gas regulator defective

REMEDY 

1. Press in control knob fully

2. After ODS/pilot lights, keep control 

knob pressed in 30 seconds

3. Wait one minute for safety in-

terlock system to reset. Repeat 

ignition operation

4. Fully open equipment shutoff 

valve

5. A) Contact local natural or pro-

pane/LP gas company 

5  B) Clean ODS/pilot

 (see Cleaning 

and Maintenance, 

Page 16

or 

replace ODS/pilot assembly 

6. Hand tighten until snug, then 

tighten 1/4 turn more

7. Replace pilot assembly

8. Replace control valve

1. Contact local natural or propane/

LP gas company

2. Clean  burner 

(see Cleaning and 

Maintenance, 

Page 16

)

 or replace 

burner orifice(s)

3. Reconnect leads see 

wiring diagram

Page 18

4. Put remote selector in ON posi-

tion

5. See 

Wiring Diagram

Page 18

1. Contact local natural or propane/

LP gas company

2. Clean  burner 

(see Cleaning and 

Maintenance, 

Page 16

or replace 

burner orifice(s)

3. 

Contact qualified service person

1. Clean  burner 

(see Cleaning and 

Maintenance, 

Page 16

)

 or replace 

burner orifice

2. Replace damaged burner

3. Replace gas regulator

OBSERVED PROBLEM

ODS/pilot lights but flame goes out 

when control knob is released

Burner does not light after pilot is lit

Delayed ignition of burner

Burner backfiring during combustion

TROUBLESHOOTING

Continued

f i r e - p a r t s . c o m

Summary of Contents for LMF30GT

Page 1: ...warnings exactly could result in serious injury death or property damage INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WHEN USED AS AN OUTDOOR APPLIAN...

Page 2: ...r maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional information consult a qualified installer servi...

Page 3: ...on adjacent walls and furniture 9 Do not use this appliance as a wood burning appliance Use only the logs provided with the appliance Do not burn solid fuels in this appliance 10 Do not run appliance...

Page 4: ...ELECTRONIC IGNITION SYSTEM This appliance has an electronic igniter to light appliance fuel supply INSTALLATION WARNING Aqualified service person must install appliance Follow all local codes NOTICE...

Page 5: ...accessory Even if noncombustible material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 3 and Figures 4 and 5 Page 6 for minimum clearances IMP...

Page 6: ...mum Non Combustible Material Height Distances to Underside of Mantel Top of Fireplace Opening Underside of Mantel Shelf 12 A 18 20 22 24 All minimum distances are in inches 2 1 2 6 8 10 Mantel Shelf M...

Page 7: ...ensure adequate air flow and guard against sooting and controls being dam aged Raisefireplacefloorwithnoncombustible material Make sure material is secure Installation Items Needed hardware package pr...

Page 8: ...This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged appliance valves WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Figure...

Page 9: ...gas supply pressure for purpose of input adjustment Figure 12 Gas Connection Pipe Cap Tee Nipple Joint Gas Control 3 Minimum Sediment Trap Equipment Shutoff Valve With 1 8 NPT Tap Approved Flexible G...

Page 10: ...re removed from appliance for install remote ac cessory replace logs see Installing Logs and Volcanic Stone Page 11 10 Place remote receiver on fireplace floor next to control valve Make sure the remo...

Page 11: ...lation instructionsinthismanual Flamescontacting logs will create soot LOG PLACEMENT It is very important to install these logs exactly as instructed Do not modify logs Only use logs supplied with app...

Page 12: ...embly by inserting it from the left side as shown in Figure 19 You will need to twist the log slightly to get it to fit against the burners properly It will rest even with the back edge of the pan Bac...

Page 13: ...forward The log has a notch that fits around the burner tube on the right side The left side of the burner tube fits into the notch on the back side of this log The log is placed properly when it sits...

Page 14: ...round hole that fits over the round peg that is on the top of the back left log The right end of this log has a rectangular hole that fits over the rectangular peg on the top of the right crossover l...

Page 15: ...smell gas go on the next step 6 Press in and turn control knob counterclockwise to the PILOT position Press in control knob for five 5 seconds see Figure 26 7 With control knob pressed in press and r...

Page 16: ...rnersandcirculatingairpassagewaysofap plianceclean Inspecttheseareasofappliance before each use Have appliance inspected yearly by a qualified service person WARNING Failure to keep the primary air op...

Page 17: ...ilot shown Thermocouple Thermopile 1 8 Pilot Burner Piezo Igniter 3 8 to 1 2 LOGS If you remove logs for cleaning refer to Installing Logs and Volcanic Stone Page 11 to properly replace logs Replace l...

Page 18: ...ure in of water Max 14 W C Min 11 W C For purpose of input adjustment MNF30ONM Rating Variable 29 000 40 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in...

Page 19: ...lled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not cor rect REMEDY 1 Reconnect igniter cable 2 Free igniter cable if pinched by any metal or tubing Keep i...

Page 20: ...eep control knob pressed in 30 seconds 3 Wait one minute for safety in terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or pro pane LP g...

Page 21: ...line Have gas line checked by local natural or pro pane LP gas company 3 Observe minimum installation clearances see Pages 4 6 4 Clean burner see Cleaning and Maintenance Page 16 or replace burner or...

Page 22: ...e LP only 3 Gas leak See Warning state ment at top of page 1 Low line pressure 2 ODS pilot is partially clogged 1 Gas leak See Warning state ment at top of page 2 Control valve or gas control de fecti...

Page 23: ...ONTROL KIT MRC REMOTE READY MODELS ONLY Cat No F1077 Model MRC For all models Allows the fireplace to be turned on and off by using a hand held remote control WALL MOUNT ON OFF SWITCH REMOTE READY MOD...

Page 24: ...eplaces us com 900467 01B 24 PARTS REMOTE READY CONTROL MODELS MNF30ONM and MNF30OPM 1 2 5 6 8 9 10 13 14 15 16 17 18 19 20 21 23 24 25 22 11 12 12 7 3 4 Cat No Model F2128 MNF30ONM F2130 MNF30OPM fir...

Page 25: ...r Electric 1 15 J6144 Bracket Igniter 1 16 J5198 Shutter Air NG 1 J5199 Shutter Air LP 1 17 J3604 Orifice 0 12 NG 1 J3615 Orifice 0 07 LP 1 18 J6127 Orifice Holder 90 Degrees 1 19 J4733 Nut and Sleeve...

Page 26: ...r assembly The next two numbers indicate the set size 2 6 3 9 1 7 8 5 4 KEY NO CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J6516 D 019 J6527 D 027 Log Front Right 1 2 J6517 D 018 J6528 D 026 Log Bac...

Page 27: ...d under Re placement Parts on Page 28 of this manual KEY NO CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8254 D 018 J8260 D 026 Log Back Left 1 3 J8255 D...

Page 28: ...If you encounter any problems or have any questions con cerning the installation or application of this appliance please contact your dealer SERVICE HINTS When Gas Pressure Is Too Low pilot will not...

Page 29: ...xcessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages re...

Page 30: ...your local distributor for fireplace code information Printed in U S A 2015 Innovative Hearth Products P N 900467 01 Rev B 01 2019 SuperiorFireplaces us com Record the following important information...

Reviews: