background image

33

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Installation Instructions

900358-00, 01/2018

Innovative Hearth Products
DRT63STTYN Power-Vent Direct-Vent Fireplaces

ATTACHING SAFETY IN OPERATION  

WARNINGS

It is required that the set of safety instruction labels 

that have been furnished with the fireplace be affixed 

to the operation and control points of the fireplace. A 

safety instruction label must be affixed to the receiver 

wall switch plate where the fireplace is turned on 

and off 

(See 

Figure A

)

 and on the remote control 

handheld transmitter 

(See 

Figure B

)

.  To properly 

complete the installation of this fireplace, locate the 

multi-lingual adhesive labels provided with the Care 

and Operation Instructions and proceed as follows:

1.  Locate the wall receiver that controls the fireplace 

(verify the switch operates the fireplace by turn-

ing it on and off).  Clean the wall receiver plate 

thoroughly to remove any dust and oils. Affix 

the label to the surface of the plate of the wall 

receiver  that controls the fireplace 

(

Figure A

)

.  

Choose the language primarily spoken in the 

home. If unknown, affix the English language 

label.

2. Locate the remote control transmitter and 

clean it thoroughly to remove any dust and 

oils.  Affix the label to the surface of handheld 

transmitter 

(

Figure B

)

.  Choose the language 

primarily spoken in the home. If unknown, affix 

the English language label.

3.  If you are unable to locate the labels, please 

call Innovative Hearth Products or your nearest 

Innovative Hearth Products dealer to receive ad-

ditional safety instruction labels free of charge.

Cat. No. H8024 Replacement Label Kit 

INNOVATIVE HEARTH PRODUCTS

SuperiorFireplaces.us.com

NOTE: English is red text on clear label. French 
and Spanish are white text on black label.

APPOSITION DES MISES EN GARDE RELATIVES  

À LA SÉCURITÉ D’UTILISATION

Il est impératif que le jeu d’étiquettes de sécurité qui 

ont été fournies avec le foyer soient collées à côté 

des dispositifs de contrôle du foyer. Une étiquette de 

sécurité doit être collée sur la plaque du récepteur mural 

contrôlant l’allumage du foyer 

(voir 

Figure A

)

 et sur le 

boîtier de la télécommande 

(

Figure B

)

.  Pour achever 

l’installation correcte de ce foyer, procédez comme suit 

avec les étiquettes adhésives en langues étrangères 

fournies avec les instructions d’utilisation et d’entretien :

1.  Repérez le récepteur mural qui contrôle le foyer 

(vérifiez que l’interrupteur contrôle le fonction -

-nement du foyer en le faisant basculer de Marche 

à Arrêt, et vice-versa).  Nettoyez soigneusement  

la plaque du récepteur mural pour éliminer la 

poussière et les traces de graisse ou d’huile. Collez 

l’étiquette sur la surface de la plaque du récepteur 

mural qui contrôle le foyer 

(

Figure A

)

.  Choisissez 

la langue qui est principalement parlée dans la 

résidence du propriétaire. En cas de doute, collez 

l’étiquette en anglais.

2.  Repérez la télécommande et nettoyez-la soigneuse-

ment pour éliminer la poussière et les traces  

de graisse ou d’huile.  Collez l’étiquette sur le boîtier 

de la télécommande 

(

Figure B

)

.  Choisissez la  

langue qui est principalement parlée dans la  

résidence du propriétaire. En cas de doute, collez 

l’étiquette en anglais.

3.  Si vous ne trouvez pas les étiquettes, veuillez  

appeler Innovative Hearth Products ou votre distribu-

teur Innovative Hearth Products local pour recevoir 

gratuitement des étiquettes supplémentaires.

Étiquettes de remplacement, n° cat. H8024 

INNOVATIVE HEARTH PRODUCTS

SuperiorFireplaces.us.com

Remarque : Le texte anglais est rouge sur un support 

transparent. Le texte français et espagnol est blanc 

sur un support noir.

COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD 

EN OPERACIÓN

Se requiere que el juego de etiquetas de instrucciones  

de seguridad que se incluyeron con la chimenea se 

coloque en los puntos de operación y control de la 

misma. Se debe colocar una etiqueta de instrucciones 

de seguridad en la placa del interruptor de pared  

del receptor desde el cual se enciende y se apaga  

la chimenea 

(ver la 

Figura A

)

 y en el transmisor de  

control remoto 

(ver la 

Figura B

)

. Para completar 

correctamente la instalación de esta chimenea, 

encuentre las etiquetas adhesivas multilingües  

incluidas con las instrucciones de cuidado y operación 

y haga lo siguiente:

1.  Identifique el receptor de pared que controla la 

chimenea (verifique que el interruptor opera la 

chimenea encendiéndola y apagándola). Limpie  

bien la placa del receptor de pared para quitar el 

polvo y aceite. Pegue la etiqueta en la superficie 

de la placa del receptor de pared que controla la 

chimenea 

(

Figura A

)

.

 

Seleccione el idioma que 

más se habla en la casa. Si no sabe cuál es, use la 

etiqueta en inglés.

2.  Identifique el transmisor de control remoto y límpielo 

bien para quitar el polvo y aceite. Pegue la etiqueta 

en la superficie del transmisor 

(

Figura B

)

. Seleccione 

el idioma que más se habla en la casa. Si no sabe 

cuál es, use la etiqueta en inglés.

3.  Si no puede encontrar las etiquetas, sírvase llamar 

a Innovative Hearth Products o al distribuidor de 

Innovative Hearth Products más cercano para  

recibir etiquetas de instrucciones de seguridad 

adicionales gratuitas. 

Juego de etiquetas de repuesto - Nº de cat. H8024 

INNOVATIVE HEARTH PRODUCTS

SuperiorFireplaces.us.com

Nota: La etiqueta en inglés es transparente con texto 

rojo. Las etiquetas en francés y español son negras 

con texto blanco.

STEP 12. INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS

It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a 

critical step in informing consumers of safe operation of this appliance.

SAFETY LABEL  

DIAGRAMS

Remote

Off

On

PRG

DIAGRAMAS DE ETIQUETAS  

DE SEGURIDAD

DIAGRAMMES DES ÉTIQUETTES 

DE SÉCURITÉ

Figure A

Figure B

Illustrations are for example only. Your 
accessories may be different.

Les illustrations sont par exemple 
uniquement. Vos accessoires peuvent être 
différents.

Las ilustraciones son sólo ejemplos. Tu 
accesorios pueden ser diferentes.

Summary of Contents for DRT63

Page 1: ...re fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent trea...

Page 2: ...UN ENFANT DE TOUCHER LA VITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le...

Page 3: ...toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidr...

Page 4: ...tits les jeunes enfants et toute autre personne risque d avoir acc s la pi ce et aux surfaces chaudes GENERAL INFORMATION PACKAGING Fireplace Components 1 Literature Kit this manual 1 Remote Control K...

Page 5: ...of the control system and any gas control which have been under water Ne pas utiliser cet appareil s il a t plong m me partiellement dans l eau Appeler un technicien qualifi pour inspecter l appareil...

Page 6: ...des latest edition Gas Supply Pressure Requirements continued from previous page Test gauge connections are provided on the front of the electronic gas control valve identi fied IN for the inlet and O...

Page 7: ...ON For cold climate installations seal all cracks around the appliance with noncombustible material and wherever cold air could enter the room If the floor is above ground level it is especially impor...

Page 8: ...f vent General Information 900358 00 01 2018 Innovative Hearth Products DRT63STTYN Power Vent Direct Vent Fireplaces Figure 3 Horizontal Power Vent Termination Clearances to Combustibles For recess al...

Page 9: ...tu h 15 kW 12 300 mm for fireplaces 50 000 Btu h 15 kW 6 150 mm for fireplaces 10 000 Btu h 3 kW 12 300 mm for fireplaces 10 000 Btu h 3 kW K Clearance to a mechanical air supply inlet 36 910 mm above...

Page 10: ...fireplace and may butt against the front face of the fireplace see Figures 5 and 6 Also note the following Combustible material may project beyond the sides of the fireplace opening as long as it is...

Page 11: ...r on the underside of the mantel 7 178 2 51 4 102 6 152 8 203 10 254 12 305 9 229 13 330 17 432 15 381 11 279 Side View Inches millimeters Mantel Depth Minimum Distance to Unprotected Side Wall Top of...

Page 12: ...may be in direct contact with the nailing flanges and may be located closer than 1 2 inch from screw heads and the firebox wrapper in areas adjacent to the nailing flanges Frame the opening to the ex...

Page 13: ...ireplace must be installed on the indoor side Dimension B is from fireplace base to top framing member Dimension C is from fireplace base to centerline of horizontal vent pipe Minimum vent framing Ada...

Page 14: ...nner 7 1 2 Outer Adaptor Probe assembly cat no H8313 required to transition from fireplace vent collar to vent pipe 50 1 2 1283 29 5 8 753 12 3 8 314 5 1 8 130 41 1 2 1054 33 3 4 857 34 3 4 883 13 1 8...

Page 15: ...e Side of Fireplace Framing 19 1 2 495 mm Right Side Front Corner Of Fire place Framing Step 2 ROUTE GAS LINE NOTICE For indoor outdoor installations the CONTROL SIDE of the fireplace must be installe...

Page 16: ...semblyupside down as shown 2 Remove the four screws securing the vent restrictor in place Lift out the vent restrictor 3 Install the appropriate vent restrictor using the four screws previously remove...

Page 17: ...0 1 1 0 1 1 5 8 1 4 5 7 8 4 3 0 0 0 0 9 9 5 6 4 5 7 8 3 0 0 0 0 0 1 0 1 5 5 7 4 5 2 6 9 3 0 1 0 0 0 1 1 1 0 8 4 0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2...

Page 18: ...i ous section until it fully engages then twist the component clockwise running the dimples down and along the incline channels until they seat at the end of the channels This seating position is indi...

Page 19: ...ime vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Adaptor Probe Assembly Required NOTICE...

Page 20: ...Install support straps every 3 feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape See Figure 21 on Page 19 HORIZONTAL OUTSIDE WALL TERMINATION SYSTEM See Figures 21 an...

Page 21: ...including theuseofsiliconecaulkingwhererequired To help minimize water infiltration it isrecom mended that the Firestop Spacer SV4 5HF be installed on the exterior side of the wall Power Vent Termina...

Page 22: ...e electrical wiring refer to Figure 25 Standard Instruction For use when access to the termination is difficult because of height or other reasons Locate a locally procured electrical junction box wit...

Page 23: ...sen the strain relief on the termination shown in Figure 28 Pull the pigtail in and shorten it to fit within the junction box cover Route 14 gauge AWG grounded Romex wiring not provided from fireplace...

Page 24: ...tall ing the glass door frame Donotattempttosubstitutethe materials used on this door or replace cracked or broken glass with any materials other than those provided by the appliance manufacturer The...

Page 25: ...r tighten or refasten the leaking connection then retest as described above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution D Reinstall the access plate ma...

Page 26: ...l Side top view of burner shown Place glowing ember material in circled areas ONLY Do NOT place glowing ember material over main flame gas ports To prevent flame impingement and soot do not use more e...

Page 27: ...r Log B FIREBOX ACCESSORIES PARTS Cat No Model Description H8312 PGE Bag of Platinum Glowing Embers 80L42 FDVS Bag of Volcanic Stone Table 9 LOG SET Item Description Item Description A Log Center D Lo...

Page 28: ...e finger Rest the other end of the log on the Landing on Center Log A Figure 46 9 10 See Figure 46 Place hole on underside of Top Left Log E over pin on Center Log A 9 9 Place groove on underside of T...

Page 29: ...Install the new approved factory barrier with flatsideofbarriertowardfirebox ifappropriate 2 Remove the modesty panel from the top flange of the glass door by firmly pulling up on it with both hands...

Page 30: ...er flame appearance is a flame that is blue at the base and becomes yellowish orange in the body of the flame When the appliance is first lit the entire flame may be blue and will graduallyturnyellowi...

Page 31: ...le Finished Wall Materials Wall Stud Top of Door Frame FIREPLACE side view Top of Appliance Spacers Insulation is NOT ALLOWED in clearance zones around vent components Keep this area free from combust...

Page 32: ...front lip of each Mounting Bracket and then align the holes Step 5 Slide the openings in the bottom edge of the Safety Guard over the Spring Nut Clips Step 6 Align the holes in the top of the Outdoor...

Page 33: ...e ment pour liminer la poussi re et les traces degraisseoud huile Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propr...

Page 34: ...with a storm collar H5816 750 247M SV4 5 TWSK Through Wall Shield Kit used to shield direct vent pipe from blown insulation Ref doc P N 750247M 96K93 SV4 5SU Support Strap 96K92 SV4 5SP Support Plate...

Page 35: ...H7952 Liquid Propane to Natural Gas Conversion Kit Table 10 Gas Conversion Kit Instructions P N 506020 44 GAS CONVERSION KITS Gas conversion kits are available to adapt your appliance from the use of...

Page 36: ...eunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison...

Page 37: ...eur mural qui contr le le foyer Figure A Choisissez la langue qui est principalement parl e dans la r sidence du propri taire 2 Rep rez la t l commande et nettoyez la soigneuse ment pour liminer la po...

Page 38: ...CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas...

Page 39: ...r is required to operate these units These models come standard with a remotely modulated gas valve The included transmitter remotely controls flame appearance and heat output manual gas valve adjustm...

Page 40: ...m hot surfaces AVERTISSEMENT Lesjeunesenfantsdevraient tresurveill s troitementlorsqu ilssetrou ventdanslam mepi cequel appareil Lestoutpetits lesjeunesenfants ou les adultes peuvent subir des br lure...

Page 41: ...rner turns on A single beep from the Receiver will confirm reception of the command Turn OFF the Appliance Press the ON OFF Key on the Transmitter The Transmitter LCD display will only show the room t...

Page 42: ...ing the three position slider switch to the ON position This will bypass the remote control feature of the system and the appliance main burner will come on if the gas valve is in the ON position Figu...

Page 43: ...e combustion Inspect Wiring Refer to wiring diagram on Page 49 CAUTION Label all wires prior to disconnec tion when servicing controls Wiring errors cancauseimproperanddangerousoperation Verify proper...

Page 44: ...the top of the door held away from the fireplace see Figure 63 c Lower the bottom of the door assembly onto the bottom door track engaging and centering it in the base channel and then gently swing th...

Page 45: ...soot do not use more ember material than necessary c For best glowing effect replace ember material annually NOTE Use only catalog number H8312 Platinum Glowing Embers with this fireplace Control Sid...

Page 46: ...B FIREBOX ACCESSORIES PARTS Cat No Model Description H8312 PGE Bag of Platinum Glowing Embers 80L42 FDVS Bag of Volcanic Stone Table 5 LOG SET Item Description Item Description A Log Center D Log Top...

Page 47: ...the other end of the log on the Landing on Center Log A Figure 73 10 See Figure 19 Place hole on underside of Top Left Log E over pin on Center Log A 9 Place groove on underside of Top Right Log D ove...

Page 48: ...ew more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation...

Page 49: ...TION Model Number_________________________________________________________ Serial Number_________________________________________________________ Date Installed _______________________________________...

Page 50: ...Andiron Kits Cat No Model Description H2227 AKM LSM Andirons Mission H2228 AKC LSM Andirons Classic Touch Up Paint Kit Repair of minor scratches and discoloration of the appliances black painted surfa...

Page 51: ...e beauty of the fireplace Dual Arch Screen Kits Cat No Model Description H5051 DASK LSM40 2 Dual Arch Screen Classic Screen Kits Cat No Model Description H5052 SK LSM40 2 Classic Screen Kit Outdoor Ki...

Page 52: ...e 9 Slide the switch on the receiver to REMOTE 10 Press ON OFF button on transmitter to ON 11 Set thermostat on remote control to desired setting 12 If the appliance will not operate follow the instru...

Page 53: ...suivante 8 Mettez l appareil sous tension 9 Placez l interrupteur du r cepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour s lectionner ON 11 Ajustez le thermostat sur la t l commande l a...

Page 54: ...essive condensation can cause corrosion of caps pipe and fittings excessive condensation can be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold...

Page 55: ...s supply and gas shutoff valves call a service technician if required B Air in gas line Call a service technician C Loose wires to valve Check control compartment for any obvious loose wiring call a s...

Page 56: ...e Hose From The Blower To The Pressure Switch Are the Hose Connections Loose Is The Hose Cracked Replace Pressure Switch Replace Control Module Yes Yes Is The Lead To The Spark Electrode Attached Or A...

Page 57: ...35 Receiver Kit H7277 1 36 Receiver Cable Harness H8008 1 37 AC DC Power Adaptor H8006 1 38 Transmitter Kit H7275 1 39 Ground Wire H7278 1 44 Power Vent Module H7367 1 Item No Description Cat No Qty...

Page 58: ...8 00 01 2018 Innovative Hearth Products DRT63STTYN Power Vent Direct Vent Fireplaces 22 REPLACEMENT PARTS ILLUSTRATION Circled numbers correspond to Replacement Parts List on previous page 1 2 4 18 25...

Page 59: ...Ring Terminal 10 2 7 H7384 Insulated 1 4 Male Terminal 4 8 H7371 Hose Clamp 11 32 2 15 H7372 Base Assembly Power Vent 1 16 H7378 Kicker Assembly 1 POWER VENT REPLACEMENT PARTS Item Part Number Descri...

Page 60: ..._____________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________________...

Page 61: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Page 62: ...ial number Date fireplace was Installed Type of gas fireplace uses Dealer name Printed in U S A 2014 Innovative Hearth Products P N 900358 00 Rev C 01 2018 1769 East Lawrence Street Russellville AL 35...