ADJUSTING AND MOUNTING TOOLS
The Holder A41 in
LAVINA® X can work with either 3 or 6 buffers
which will change its elasticity. You can make the change after
dismounting the holder as per the instruction in
TROUBLESHOOTING.
In Lavina 20G-X the holder is initially mounted with 3 buffers.
Mount the tools only after ensuring that there is enough
diamond bond material left. Be sure that the plates are
always clean before mounting.
VACUUM CONNECTION
To connect a vacuum cleaner, the Lavina 20G-X
is supplied with
vacuum hose Cam Lock inlet C250 /
vacuum hose
diam. 2,5 in (63mm)
(Fig.4.9-2). You can also dismount the Cam Lock adaptor (Fig.4.9-1) and connect a hose with outside
diam. 2in (Fig.4.10).
Figure 4.8
Figure 4.7
Figure 4.5
Figure 4.6
Figure 4.10
Figure 4.9
WARNING: Always Secure the Quick Change tools with the security ring (Fig.4.3 in red), lock with the tool holder key (Fig.4.4)
and make sure that the butterfly is securely locked at 90 degrees.
Diamond tools with Velcro are attached on three foam plates (9 inch). The foam plates are mounted on the key lock (butterfly).
Always use the tool holder key (Fig.4.4).