![Superabrasive LAVINA 16-S-E User Manual Download Page 14](http://html1.mh-extra.com/html/superabrasive/lavina-16-s-e/lavina-16-s-e_user-manual_1402111014.webp)
Superabrasive
Owner’s Manual Original Language LAVINA
®
16-S-E
6/2014
14
9. TROUBLESHOOTING
INDEX OF PROBLEMS AND SOLUTIONS
9.1 REPLACING POWER CORD AND PLUGS
When replacing the power cord or plugs always use cords and plugs with specifications as the original ones.
Never use lower quality or different type cord and plugs.
In addition, take into consideration is the distance of the appliance from the electrical source. The greater the
distance, the greater the resistance and the less current that will be available at the other end, there will be a
voltage drop and the inverter will sign alarm mode. This also happen if several machines are working on the same
line or when the generator is underrated. In general our standard power cable can be doubled in length, if longer
lengths needed you have replace all the cables with cables with bigger gage rated for the length and amperage.
9.2 DISMOUNTING AND MOUNTING TOOL HOLDER TO CHANGE BUFFERS AND SPIDERS, CHANGING
SEALERS
To check or replace the buffers and the spiders, the tool holders have to be dismounted.
Remove the countersunk screws on top of the buffer (Fig.9.2.1). Take the disc off
(Fig.9.2.2), the spider can be removed or replaced (Fig.9.2.3). By loosing four Hex cap
bolts (Fig.9.2.4), the disc comes loose (Fig.9.2.5; Fig.9.2.6) and the buffers can be
replaced(Fig.9.2.9). Attention, by mounting use always the “blue” thread locking adhesive,
except on the bolts to lock the buffers. Use always original bolts(Fig.9.2.7).
Depending on the number (3 or 6) of buffers, the holder can be more flexible or rigid.
When the tool holder is dismounted, you can change the sealers(Fig.9.2.8).
Take out Adaptor with sealer and change it.
Figure 9.2.1
Figure 9.2.2
Figure 9.2.3
Figure 9.2.4
Figure 9.2.5
Figure 9.2.6
Figure 9.2.7
Figure 9.2.8
Figure 9.2.9